2015
DOI: 10.1590/s1984-82502015000400007
|View full text |Cite
|
Sign up to set email alerts
|

A green approach for the quantification of daptomycin in pharmaceutical formulation by UV spectrophotometry

Abstract: Daptomycin is the first approved drug from a new class of antimicrobials, the cyclic lipopeptides, and is a very important antimicrobial agent in current clinical practice. Currently, there are no "green" analytical methods described in the literature to analyze the typical pharmaceutical dosage form of daptomycin. Thus, the aim of this work was to validate an environment-friendly spectrophotometric method in the UV region, for the analysis of daptomycin as a lyophilized powder. Water was used as diluent and t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 9 publications
(10 citation statements)
references
References 27 publications
0
10
0
Order By: Relevance
“…[62][63][64][65] However, it is a non-selective method and is not suitable for the detection of degradation products and impurities. [66] Spectrophotometric methods are also found in literature for other fluoroquinolones, such as ciprofloxacin, [67] norfloxacin, [68,69] orbifloxacin, [70] lomefloxacin, [71] gatifloxacin, [72] and sparfloxacin. [73,74] Costa et al (2014) developed and validated a microbiological agar diffusion method for the potency analysis of besifloxacin in ophthalmic suspension.…”
Section: Uv (289 Nm)mentioning
confidence: 99%
“…[62][63][64][65] However, it is a non-selective method and is not suitable for the detection of degradation products and impurities. [66] Spectrophotometric methods are also found in literature for other fluoroquinolones, such as ciprofloxacin, [67] norfloxacin, [68,69] orbifloxacin, [70] lomefloxacin, [71] gatifloxacin, [72] and sparfloxacin. [73,74] Costa et al (2014) developed and validated a microbiological agar diffusion method for the potency analysis of besifloxacin in ophthalmic suspension.…”
Section: Uv (289 Nm)mentioning
confidence: 99%
“…Chromatographic methods, such as thin‐layer chromatography (TLC), high‐performance thin‐layer chromatography (HPTLC), TLC densitometric analysis, gas chromatography, high‐performance liquid chromatography (HPLC) and ultra‐performance liquid chromatography (UPLC), for their great power and resolution, are extensively used for the qualitative identification and quantification of GA in different matrices. On the other hand, for good results, these methods require a correct selection of both stationary and mobile phases and retention times, which depend on the gradient system used in the analysis, can be very different.…”
Section: Introductionmentioning
confidence: 99%
“…The CVs showed two oxidation peaks, the first a well‐defined, oxidation peak P1, at E pa1 =+0.85 V for pH 4.0, Figure , and at E pa1 = + 0.74 V for pH 7.0, and the second a smaller oxidation peak P2, at E pa2 =+ 0.85 V for pH 4.0, and at E pa2 = + 1.05 V for pH 7.0. Reversing the scan direction, no reduction peak appeared for either pH, indicating that the oxidation process is irreversible . Recording successive scans in the same solution, without cleaning the electrode surface, both peak currents decreased, due to the adsorption of DPT and/or its oxidation products at the GCE surface, Figure 1.…”
Section: Resultsmentioning
confidence: 99%
“…The scan rate effect on the oxidation process of DPT oxidation peak P1 was investigated recording CVs, in 25 μM DPT, in 0.1 M phosphate buffer pH 7.0, at scan rates between 5–50 mVs −1 , always using a clean GCE. The oxidation peak P1 current, I pa (A)=2.69 × 10 5 n (α c n ’) 1/2 A [R] ∞ D O 1/2 ν 1/2 , increased linearly with ν 1/2 , indicating that the oxidation process was diffusion‐limited and the value of the DPT diffusion coefficient in 0.1 M phosphate buffer pH 7.0, was calculated as D DPT = 2.32 × 10 −5 cm 2 s −1 . The GCE electroactive area, A =4.17 × 10 −3 cm 2 , was determined using 1.0 mM hexacyanoferrate(II) in phosphate buffer solution ( D O = 7.35 × 10 −6 cm 2 s −1 ).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation