A generic high-dose rate192Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism

Abstract: A hypothetical, generic HDR (192)Ir source was designed and implemented in two commercially available TPSs employing different MBDCAs. Reference dose distributions for this source were benchmarked and used for the evaluation of MBDCA calculations employing a virtual, cubic water phantom in the form of a CT DICOM image series. The implementation of a generic source of identical design in all TPSs using MBDCAs is an important step toward supporting univocal commissioning procedures and direct comparisons between… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
59
0
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 67 publications
(62 citation statements)
references
References 48 publications
(71 reference statements)
2
59
0
1
Order By: Relevance
“…Difference between IRAsource model and other similar 192Ir‐HDR sources in common use 13 , 14 , 15 , 16 , 17 is listed in Table 1. All HDR sources have similar active length and active core diameter and are all encapsulated in stainless steel tubes.…”
Section: Methodsmentioning
confidence: 99%
“…Difference between IRAsource model and other similar 192Ir‐HDR sources in common use 13 , 14 , 15 , 16 , 17 is listed in Table 1. All HDR sources have similar active length and active core diameter and are all encapsulated in stainless steel tubes.…”
Section: Methodsmentioning
confidence: 99%
“…This balance has been optimized for 192 Ir sources in the current software, and cannot be modified by the user. A potential issue with angular discretization methods is the presence of ‘ray-line’ artifacts in the dose distribution, however these have been essentially eliminated in AcurosBV [16]. Early versions of the software reported only dose to water for photon transport in full medium, D w,m ; however, since 2013, the user has been offered a choice between D m,m and D w,m [8].…”
Section: Commercial Treatment Planning Systems Incorporating Model-bamentioning
confidence: 99%
“…Parameters in the calculation that influence accuracy and over which the user is given limited control include the numbers of photon transport directions (coincident with the collapsed cone axes) for once- and multiply-scattered photons. As for AcurosBV, angular discretization (in the form of photon transport directions) brings with it the possibility of ‘ray-line’ artifacts, which for ACE are comparatively more pronounced, but of limited clinical concern [16]. A comprehensive description of the implementation can be found in a recent publication dedicated to the topic [9].…”
Section: Commercial Treatment Planning Systems Incorporating Model-bamentioning
confidence: 99%
See 2 more Smart Citations