2006
DOI: 10.1016/j.jmr.2006.06.033
|View full text |Cite
|
Sign up to set email alerts
|

A general numerical analysis of time-domain NQR experiments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 22 publications
0
5
0
Order By: Relevance
“…The zero-field NQR spectrum of an I = 3 / 2 nuclide consists of one line corresponding to the doubly degenerate transition. The 35 Cl line found by time domain methods at 6.350 MHz, is presented in Figure ; the corresponding 37 Cl NQR transition frequency is predicted to be 5.047 MHz, which lies outside the operational bandwidth of the spectrometer.…”
Section: Resultsmentioning
confidence: 92%
See 1 more Smart Citation
“…The zero-field NQR spectrum of an I = 3 / 2 nuclide consists of one line corresponding to the doubly degenerate transition. The 35 Cl line found by time domain methods at 6.350 MHz, is presented in Figure ; the corresponding 37 Cl NQR transition frequency is predicted to be 5.047 MHz, which lies outside the operational bandwidth of the spectrometer.…”
Section: Resultsmentioning
confidence: 92%
“…NQR. Time domain NQR experiments 44 were performed at room temperature with a Tecmag Discovery 3 spectrometer and home-built probes. Signals were acquired with a two-pulse Hahn echo 45 with a 16 step phase cycle 46 and dephasing times ranging between 50 and 100 μs.…”
Section: +mentioning
confidence: 99%
“…If it is known a priori that Z Q a 0, one could venture into overtone NQR measurements to arrive at unambiguous EFG tensor parameters for each site, but such experiments are exceedingly insensitive or otherwise time consuming. 90,[130][131][132][133] Although the solution space is not extensive, to rapidly establish the set of 185/187 Re EFG tensor parameters for Ca(ReO 4 ) 2 Á2H 2 O, we undertook the intuitive, although novel, approach for a system with multiple sites, 134 which simultaneously fits all the SSNMR/NQR data. In essence, the NQR data were used to begin the process with several 'test' solutions as to what the expected 185/187 Re SSNMR spectrum would look like under the assumption that the NQR data had been assigned correctly.…”
Section: Resultsmentioning
confidence: 99%
“…The NQR signal was detected in the time domain by spin echo methods. , The broad-band radio frequency amplifier output was adjusted at each temperature to avoid voltages that would cause arcing in the probe circuit. Pulse times were calibrated for the maximum echo response.…”
Section: Methodsmentioning
confidence: 99%