2013
DOI: 10.1016/j.aca.2013.03.016
|View full text |Cite
|
Sign up to set email alerts
|

A fluorescence ratiometric sensor for hypochlorite based on a novel dual-fluorophore response approach

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
50
0
2

Year Published

2015
2015
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 127 publications
(53 citation statements)
references
References 40 publications
0
50
0
2
Order By: Relevance
“…The resultant binding constant of the probe PTI with Al 3+ is 1.23 × 10 6 M −1 , obtained from the fluorescence titration (Figure S5, see Supporting Information) determined by non‐linear fitting analyses of the titration curves following the published reports . Detection limit has been well calculated from the linear relationship between PTI and Al 3+ as 45 nM (Figure S6, see Supporting Information). Job's plot reveals the 1:1 stoichiometric interactions between PTI and Al 3+ (Figure S7, see Supporting Information).…”
Section: Resultsmentioning
confidence: 99%
“…The resultant binding constant of the probe PTI with Al 3+ is 1.23 × 10 6 M −1 , obtained from the fluorescence titration (Figure S5, see Supporting Information) determined by non‐linear fitting analyses of the titration curves following the published reports . Detection limit has been well calculated from the linear relationship between PTI and Al 3+ as 45 nM (Figure S6, see Supporting Information). Job's plot reveals the 1:1 stoichiometric interactions between PTI and Al 3+ (Figure S7, see Supporting Information).…”
Section: Resultsmentioning
confidence: 99%
“…To date, as we have just seen, there have been numerous fluorescence small-molecules that have been developedf or the detection of HOCl;m any famous fluorophores sucha s1 ,8naphthalimide, coumarin, BODIPY,c yanine, rhodamine, and fluorescein have been used to detect HOCl. [70][71][72][73][74][75][76][77][78][79][80] These fluorescent molecules are embedded with receptors such as the phenylc halcogenide group, the oxime group, spiro rings, etc. to help tune the reactivity of the fluorophore.…”
Section: Discussionmentioning
confidence: 99%
“…Zhou andc o-workers reported ar atiometric fluorescent sensorc ontaining at wo fluorophore unit (coumarin and rhodamine) connected directly to each other based on ad iacylhydrazine recognitiong roup (Scheme 61). [70] Initially,t he sensor Scheme57. Rhodamine based probe for the selective detection of HOCl.…”
Section: Sensors Based On Lactone/ring Openingmentioning
confidence: 99%
See 1 more Smart Citation
“…Upon oxidation with hypochlorite, aldoxime gives the corresponding aldehyde [19][20][21]24], carboxylic acid [17], or nitrile oxide [18,23]. Many probes for detecting hypochlorite have been developed based on the mechanism of the oxidization-hydrolysis of hydrazide [39][40][41][42][43][44]. Inspired by the two strategies mentioned above, a novel probe for hypochlorite was designed by modifying the aldehyde with hydrazine group.…”
mentioning
confidence: 99%