2018
DOI: 10.1109/tpel.2017.2770141
|View full text |Cite
|
Sign up to set email alerts
|

A DC Link Sensor-Less Voltage Balancing Technique for Cascaded H-Bridge Multilevel Converters With Asymmetric Selective Harmonic Current Mitigation-PWM

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
9
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 25 publications
(9 citation statements)
references
References 21 publications
0
9
0
Order By: Relevance
“…However, in [28] only one capacitor module is considered and a predetermined switching scheme, as in [12], requires a large memory for the lookup table. In [31][32][33] it is shown that a predetermined switching pattern can be even used to operate the inverter without measuring the capacitor voltages. Nonetheless, in [31][32][33] only a symmetric MLC is considered.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, in [28] only one capacitor module is considered and a predetermined switching scheme, as in [12], requires a large memory for the lookup table. In [31][32][33] it is shown that a predetermined switching pattern can be even used to operate the inverter without measuring the capacitor voltages. Nonetheless, in [31][32][33] only a symmetric MLC is considered.…”
Section: Introductionmentioning
confidence: 99%
“…In [31][32][33] it is shown that a predetermined switching pattern can be even used to operate the inverter without measuring the capacitor voltages. Nonetheless, in [31][32][33] only a symmetric MLC is considered. In contrast, the authors of [29] suggest a self-balancing modulation scheme for binary asymmetric MLCs without measuring (sensorless) the floating capacitors' voltages.…”
Section: Introductionmentioning
confidence: 99%
“…Thus, the performance of the system is compromised. In addition, the synchronous reference frame (SRF) [12], pulsewidth modulation technique [13], extended Kalman filter [14] etc. are generally used for control of grid connected converter for synchronisation of the grid.…”
Section: Introductionmentioning
confidence: 99%
“…On the other hand, due to the reduced number of subject switches, the switching method of this topology is complex. The SHE is suggested to solve this problem in [23][24][25][26][27] and the NLC switching method is used in [28,29]. Although these methods of switching are more efficient in terms of reducing the total harmonic distortion (THD) of output voltage, these methods are offline and are used for lower switching frequency applications.…”
Section: Introductionmentioning
confidence: 99%