2017
DOI: 10.1039/c7cc05887j
|View full text |Cite
|
Sign up to set email alerts
|

A continuous luminescence assay for monitoring kinase activity: signalling the ADP/ATP ratio using a discrete europium complex

Abstract: COMMUNICATION Stephen J. Butler et al.A continuous luminescence assay for monitoring kinase activity: signalling the ADP/ATP ratio using a discrete europium complex Volume

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
49
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 42 publications
(50 citation statements)
references
References 42 publications
1
49
0
Order By: Relevance
“…Data in support of 1:1 binding between [ Eu.3 ] + and ATP or GTP was provided by high resolution (ESI) mass spectrometry, which gave intense signals at m / z= 741.6588 and 749.6564, corresponding to the doubly charged species [ Eu.3 +ATP+5H] 2+ and [ Eu.3 +GTP+5H] 2+ respectively (Figure S50 and S51). Mass spectral data showing the formation of stable ternary adducts of [ Eu.1 ] + and ATP or ADP was reported previously …”
Section: Resultssupporting
confidence: 61%
See 1 more Smart Citation
“…Data in support of 1:1 binding between [ Eu.3 ] + and ATP or GTP was provided by high resolution (ESI) mass spectrometry, which gave intense signals at m / z= 741.6588 and 749.6564, corresponding to the doubly charged species [ Eu.3 +ATP+5H] 2+ and [ Eu.3 +GTP+5H] 2+ respectively (Figure S50 and S51). Mass spectral data showing the formation of stable ternary adducts of [ Eu.1 ] + and ATP or ADP was reported previously …”
Section: Resultssupporting
confidence: 61%
“…Indeed, we have shown recently that the cooperative use of metal‐ligand interactions in combination with hydrogen bonding can provide excellent selectivity for nucleoside polyphosphate anions over monophosphate anions (e.g. AMP, cAMP, HPO 4 2− , phosphorylated amino acids), where no such hydrogen‐bonding interactions can occur . To investigate the function of the hydrogen bond‐donor groups in the ATP recognition process, we prepared two control complexes, [ Eu.2 ] + and [ Eu.4 ] + , which lack quinoline amide groups.…”
Section: Resultsmentioning
confidence: 99%
“…Owing to the partially shifted emission regions, a mixture of complexes 66 and 67 was effectively applied for monitoring enzymatic reactions catalyzed by a kinase. Sensor 68 can bind ATP and ADP in aqueous solution at neutral pH values . Unlike other cyclam complexes, 68 functions as a turn‐on probe upon addition of ADP and ATP.…”
Section: Metal‐based Receptorsmentioning
confidence: 99%
“… ATP is hydrolyzed to ADP in a series of biological processes . Thus, those systems that have excellent ATP/ADP selectivity have been explored to detect the ratio of ATP/ADP concentrations in cells . Several publications have focused on the quantification of cAMP and ATP concentrations in human blood samples.…”
Section: Application Of Receptors and Probes For Nucleotidesmentioning
confidence: 99%
“…[2] One of very few known examples of ar atiometric luminescent probe to monitor the ADP/ATP ratio is the fusion protein Perceval, consisting of ab acterial regulatory protein GInK1 and am odified green fluorescent protein GFP. [4] Europium complexes have been used extensively for selective anion binding,o ften generating ar atiometric response in emission. [4] Europium complexes have been used extensively for selective anion binding,o ften generating ar atiometric response in emission.…”
mentioning
confidence: 99%