2001
DOI: 10.1038/sj.bjp.0704169
|View full text |Cite
|
Sign up to set email alerts
|

A comparison of effects measured with isotonic and isometric recording: II. Concentration‐effect curves for physiological antagonists

Abstract: 1 If one drug, B, antagonizes another, A, by producing the opposite physiological e ect, the antagonist concentration-e ect curves should be a ected by the recording system, which limits the range of agonist responses. 2 With pieces of isolated guinea-pig ileum taken from adjacent parts of the same animal, one recorded isotonically, the other isometrically with the same load, the isotonic IC 50 values for (7)isoprenaline opposing carbachol or histamine were lower than the isometric values (P50.01) but there wa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0
1

Year Published

2010
2010
2017
2017

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(10 citation statements)
references
References 10 publications
0
9
0
1
Order By: Relevance
“…EC 50 for proscillaridin A in this assay was 2.59 × 10 −8 M. This value is in the range of usual physiological values for neuronal agonists. 32 The Z′ factor calculated for this assay was 0.85 ± 0.01. According to several authors, 33 a Z′ factor >0.5 indicates a statistically reliable separation between positive and negative controls.…”
Section: Resultsmentioning
confidence: 88%
“…EC 50 for proscillaridin A in this assay was 2.59 × 10 −8 M. This value is in the range of usual physiological values for neuronal agonists. 32 The Z′ factor calculated for this assay was 0.85 ± 0.01. According to several authors, 33 a Z′ factor >0.5 indicates a statistically reliable separation between positive and negative controls.…”
Section: Resultsmentioning
confidence: 88%
“…(the second part of (11)) and this response does not depend on the measures C 2 and c 2 of the stimulus S. From (13) it follows that the stimulus S depends on two parameters-c 2 and µ A , and the variable X. The parameter c 2 together with parameters E T m and R (see (12)) define exactly the S-R relations of the tissue and appear to be a receptor property.…”
Section: Using Notations λmentioning
confidence: 96%
“…It needs to be pointed out that µ A is just the relative efficacy e A /C 2 (relative, because the measure unit is C 2 , described in THM-2). In these terms the first equation in (11) can be rewritten as:…”
Section: Using Notations λmentioning
confidence: 99%
See 1 more Smart Citation
“…На сьогодні існують значні досягнення в з'ясуванні механізмів (іонних, молекулярних і мембранних) скоротливої активності м'язів, зокрема гладеньких [4][5][6]. Проте вивчення феноменологічних властивостей інтактного ГМ, зокрема кінетичних закономірностей процесу скорочення-розслаблення в ізометричному режимі, залишається вкрай необхідним [1,2,3]. По-перше, від-стеження зміни напруження м'язового препарату в часі робить можливим визначення об'єктивних параметрів скоротливої відповіді (наприклад, амплітуда f m та час t m , за який досягається амплітудне значення сили скорочення, а також швидкості скорочення та розслаблення).…”
Section: була розроблена оптична система реєстрації скорочення гладенunclassified