2013
DOI: 10.1007/s11814-013-0117-5
|View full text |Cite
|
Sign up to set email alerts
|

A comparative study on antibody immobilization strategies onto solid surface

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
16
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 38 publications
(17 citation statements)
references
References 13 publications
1
16
0
Order By: Relevance
“…A reduction in signal SPR was observed (points E to F) because of the detachment of some uncoupled not adsorbed, leaving only antibodies strongly connected. Comparing these data with previous studies by (Lee et al, 2013;Franco et al, 2013;Peluso et al, 2013), is confirmed affinity binding and irreversible adsorption of the antibody on the sensor surface, BSA is necessary to block the rest of the electrode surface, thereby preventing non-specific binding (point G). In Point I, the first positive urine sample with concentration 200μg/ml was added on the surface, where the total quantity of antigen immobilized on the electrode surface was estimated from the difference of SPR angle generated between points I and J, the value of the resonant unit (RU) measured by SPR was 496.6 millidegree.…”
Section: Spr Graphic For Detecting Antibody Positive and Negative Sasupporting
confidence: 85%
“…A reduction in signal SPR was observed (points E to F) because of the detachment of some uncoupled not adsorbed, leaving only antibodies strongly connected. Comparing these data with previous studies by (Lee et al, 2013;Franco et al, 2013;Peluso et al, 2013), is confirmed affinity binding and irreversible adsorption of the antibody on the sensor surface, BSA is necessary to block the rest of the electrode surface, thereby preventing non-specific binding (point G). In Point I, the first positive urine sample with concentration 200μg/ml was added on the surface, where the total quantity of antigen immobilized on the electrode surface was estimated from the difference of SPR angle generated between points I and J, the value of the resonant unit (RU) measured by SPR was 496.6 millidegree.…”
Section: Spr Graphic For Detecting Antibody Positive and Negative Sasupporting
confidence: 85%
“…Consequently, the second strategy exploited the recombinant PG whose N-terminus was tailored by means of a 6-histidine chain to immobilize the Abs in a certain orientation to the Au surface. Ideally, PG binds specifically to fragment crystallizable of Abs [40], whereas fragment antigen-binding (Fab) stretches toward the liquid phase, so that Abs can maintain their natural conformation and expose more free antigen-binding regions. Thus, controlling the directional arrangement of Abs can increase the sensitivity of the biosensor.…”
Section: Antibody Immobilization Strategies On Gatementioning
confidence: 99%
“…Rusmini et al described in depth the various schemes involved in the immobilization of protein [26]. A strong affinity towards the noble metal surfaces is exhibited by the thiol groups which allow the formation of a covalent bond between the metallic atom and the sulphur head group of thiol [27][28][29].…”
Section: Sensor Fabricationmentioning
confidence: 99%