1999
DOI: 10.1093/oxfordjournals.rpd.a032845
|View full text |Cite
|
Sign up to set email alerts
|

A Comparative Study of the Thermal Stability of LiF:Mg.Ti and LiF:Mg,Cu,P Detectors for Environmental Monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
5
0

Year Published

2003
2003
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 0 publications
1
5
0
Order By: Relevance
“…These stud ies have re ported the ex po nen tial de cay of third glow curve peak both be fore and af ter an ir ra di a tion and an in crease in the total area of fourth peak dur ing pre-and post-ir ra di a tion fad ing [43,45]. The peak four has been shown to have a high ther mal sta bil ity and fades in de pend ently of the tem per a ture whereas the low tem per a ture peaks de cay ex po nen tially and are strongly de pend ent on tem per ature [43]. The to tal TL out put has been re ported to post-ir ra di a tion fade up to 26 % [46].…”
Section: Fad Ing Re Duc Tionmentioning
confidence: 98%
See 3 more Smart Citations
“…These stud ies have re ported the ex po nen tial de cay of third glow curve peak both be fore and af ter an ir ra di a tion and an in crease in the total area of fourth peak dur ing pre-and post-ir ra di a tion fad ing [43,45]. The peak four has been shown to have a high ther mal sta bil ity and fades in de pend ently of the tem per a ture whereas the low tem per a ture peaks de cay ex po nen tially and are strongly de pend ent on tem per ature [43]. The to tal TL out put has been re ported to post-ir ra di a tion fade up to 26 % [46].…”
Section: Fad Ing Re Duc Tionmentioning
confidence: 98%
“…Sev eral well-con ducted stud ies [43][44][45][46] have inves ti gated the pre-ir ra di a tion and post-ir ra di a tion fading rates of LiF:Cu,Mg,P. These stud ies have re ported the ex po nen tial de cay of third glow curve peak both be fore and af ter an ir ra di a tion and an in crease in the total area of fourth peak dur ing pre-and post-ir ra di a tion fad ing [43,45].…”
Section: Fad Ing Re Duc Tionmentioning
confidence: 99%
See 2 more Smart Citations
“…Following the respective storage periods all three sets were readout at the same time. The storage temperature and periods were chosen in order to induce changes on full and empty traps, respectively, in irradiated and non-irradiated dosemeters (Alves et al 1999).…”
Section: Sample Sizementioning
confidence: 99%