A Compact and Noise Free Electrohydraulic Total Artificial Heart

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
4
0
1

Year Published

1997
1997
2022
2022

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 0 publications
1
4
0
1
Order By: Relevance
“…In vivo conditions, the longest period after implantation was 399 days, performing euthanasia due to the excessive growth of the animal. [13] In summary, these data demonstrate the good hemodynamic performance behavior of the implanted SPU prosthesis right side of the heart, in particular lack of a significant pressure gradient after 1 year of implantation. This study confirms the good biocompatibility of SPU (low thrombogenicity in animals without anticoagulant therapy) and short-term durability of such compounds without the use of anti-calcification in a model of accelerated mineralization.…”
Section: Durability Of Polyurethane Prosthesis Tested "In Vitro"supporting
confidence: 52%
See 2 more Smart Citations
“…In vivo conditions, the longest period after implantation was 399 days, performing euthanasia due to the excessive growth of the animal. [13] In summary, these data demonstrate the good hemodynamic performance behavior of the implanted SPU prosthesis right side of the heart, in particular lack of a significant pressure gradient after 1 year of implantation. This study confirms the good biocompatibility of SPU (low thrombogenicity in animals without anticoagulant therapy) and short-term durability of such compounds without the use of anti-calcification in a model of accelerated mineralization.…”
Section: Durability Of Polyurethane Prosthesis Tested "In Vitro"supporting
confidence: 52%
“…The SPU prostheses have shown a useful life of over 130 million cycles in real time and 420 million cycles at accelerated conditions without failure of the SPU [13]. In vivo conditions, the longest period after implantation was 399 days, performing euthanasia due to the excessive growth of the animal.…”
Section: Durability Of Polyurethane Prosthesis Tested "In Vitro"mentioning
confidence: 99%
See 1 more Smart Citation
“…10 The implantable components consist of a thoracic unit that contains an energy converter with left and right ventricles, a controller, a battery, and a secondary transcutaneous energy transmission coil. Dacron atrial cuffs and vascular grafts are anastomosed to the native atrial remnants and the great vessels, respectively, and then attached to the inflow ports and outflow conduits of the blood pump by quick connectors.…”
Section: Device Descriptionmentioning
confidence: 99%
“…Η καταναλισκόμενη ισχύς του VAD 3 ης γενιάς HeartWare είναι περίπου 4,5watt 388 . Η τεχνητή καρδιά Abiocor 389 καταναλώνει έως 30watt δημιουργώντας παροχή 10l/min. Για 6l/min, που είναι μια πιο συνηθισμένη παροχή, οι ενεργειακές απαιτήσεις είναι περίπου 18watt.…”
Section: ενεργειακές απαιτήσεις διάφορων συσκευώνunclassified