2004
DOI: 10.1016/j.joms.2004.06.030
|View full text |Cite
|
Sign up to set email alerts
|

A clinical evaluation of the zygoma fixture: One year of follow-up at 16 clinics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

5
75
0
3

Year Published

2005
2005
2020
2020

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 84 publications
(83 citation statements)
references
References 12 publications
5
75
0
3
Order By: Relevance
“…36 Since then several reports have been published on the clinical performance of zygoma implants. 28,29,31,35,[37][38][39][40][41][42][43][44][45][46] The 2 primary indications for the use of zygoma implants are atrophic edentulous maxillae and defects after maxillary resection. 28,29,40 Zygoma implants are generally placed at a 30 to 60-degree angle relative to the occlusal plane.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…36 Since then several reports have been published on the clinical performance of zygoma implants. 28,29,31,35,[37][38][39][40][41][42][43][44][45][46] The 2 primary indications for the use of zygoma implants are atrophic edentulous maxillae and defects after maxillary resection. 28,29,40 Zygoma implants are generally placed at a 30 to 60-degree angle relative to the occlusal plane.…”
Section: Discussionmentioning
confidence: 99%
“…With this specific design these implants have been successfully used to support prostheses in the atrophic edentulous maxilla, [37][38][39][40][41][42][43][44][45][46] as well as in patients which have undergone maxillectomy. 28,35,40,47 This clinical report demonstrates the use of a zygoma implant to improve stability and retention of a telescopic-crown retained [48][49][50][51] obturator prosthesis and highlights the benefits of computer-supported navigation when placing such an implant.…”
Section: Introductionmentioning
confidence: 99%
“…The aim of this new implant was to obtain a steady anchorage in the zygoma bone 7 for the posterior maxillary region bone quality type IV that does not allow insertion of standard implants, while adding two to four standard implants in the anterior region. The new protocol was first developed in a multicentre study and had a high success rate 13 . Since then, several clinicians have used the same protocol 4,13,15,16 and some have added modifications 5,26 and guidelines.…”
mentioning
confidence: 99%
“…(20)(21)(22)(23)10) Thus, technique and procedures mentioned here represent tendencies to optimize the good results obtained with this dedicated system.…”
Section: Discussionmentioning
confidence: 99%