2015
DOI: 10.1016/j.cca.2015.03.046
|View full text |Cite
|
Sign up to set email alerts
|

A clinical and laboratory approach used to elucidate discordant results of high-sensitivity troponin T and troponin I

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0
1

Year Published

2015
2015
2020
2020

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 14 publications
0
7
0
1
Order By: Relevance
“…In addition to a difference in clearance pathway, the presence of troponin-specific auto-antibodies and macro-troponins might have influenced detection of serum levels of both troponin isoforms in our cohort as well. Macro-troponins are rare but can result in inappropriately increased troponin levels, due to reduced serum clearance [ 35 , 36 ]. On the other hand, the release of cardiac troponins can stimulate the production of autoantibodies directed to cardiac-specific troponin, which interferes with troponin detection, and causes false-negative results [ 37 , 38 ].…”
Section: Discussionmentioning
confidence: 99%
“…In addition to a difference in clearance pathway, the presence of troponin-specific auto-antibodies and macro-troponins might have influenced detection of serum levels of both troponin isoforms in our cohort as well. Macro-troponins are rare but can result in inappropriately increased troponin levels, due to reduced serum clearance [ 35 , 36 ]. On the other hand, the release of cardiac troponins can stimulate the production of autoantibodies directed to cardiac-specific troponin, which interferes with troponin detection, and causes false-negative results [ 37 , 38 ].…”
Section: Discussionmentioning
confidence: 99%
“…This negative interference seems to be time dependent and can be managed by laboratories with systematic measurement of sample haemolysis. Interferences of heterophilic antibodies have also been described ( 2 ). Recently, Trambas et al described a negative interference affecting the result of troponin T by using hs-cTnT assay due to concentration of biotin above physiological value ( 3 ).…”
Section: Introductionmentioning
confidence: 99%
“…[ 2 ] In addition, false-positive test results are known with immunoassays secondary to the presence of heterophilic antibodies or human autoantibodies even though most assays contain blocking antibodies to avoid these interferences. [ 5 6 ]…”
Section: Nonacute Coronary Syndrome Causes Of Increased High-sensitivmentioning
confidence: 99%