A Certified Urea Reference Material (NMIJ CRM 6006-a) as a Reliable Calibrant for the Elemental Analyses of Amino Acids and Food Samples

Abstract: We examined the reliability of a certified reference material (CRM) for urea (NMIJ CRM 6006-a) as a calibrant for N, C, and H in elemental analyzers. Only the N content for this CRM is provided as an indicative value. To estimate the C and H contents of the urea CRM, we took into account the purity of the urea and the presence of other identified impurities. When we examined the use of various masses of the calibrant (0.2 to 2 mg), we unexpectedly observed low signal intensities for small masses of H and N, bu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
2

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…A 2400 Series II CHNS/O System elemental analyzer (PerkinElmer, Waltham, MA, USA) was used for carbon hydrogen nitrogen (CHN) analysis. The experimental procedures reported in the previous study were followed . An EPR spectrometer (Bruker, E500) was operated at the Q-band EPR to obtain EPR spectra with a higher resolution than those of the X-band.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…A 2400 Series II CHNS/O System elemental analyzer (PerkinElmer, Waltham, MA, USA) was used for carbon hydrogen nitrogen (CHN) analysis. The experimental procedures reported in the previous study were followed . An EPR spectrometer (Bruker, E500) was operated at the Q-band EPR to obtain EPR spectra with a higher resolution than those of the X-band.…”
Section: Methodsmentioning
confidence: 99%
“…The experimental procedures reported in the previous study were followed. 31 An EPR spectrometer (Bruker, E500) was operated at the Q-band EPR to obtain EPR spectra with a higher resolution than those of the X-band. The powder sample for the Q-band of less than 1 mg was sealed in an evacuated quartz tube (2 mm diameter, 100 mm length).…”
mentioning
confidence: 99%
“…The experimental procedures reported by previous studies were followed. 44,45 To obtain EPR spectra with higher resolution than those observed at X-band, EPR spectrometers (Bruker, E500 and E680) were operated at Q-and W-bands EPR, respectively, to obtain considerably higher resolution EPR spectra than those of X-band. A powdered sample for the Q-band of less than 1 mg was sealed in an evacuated quartz tube (diameter 2 mm, length 100 mm).…”
Section: Chn Analysis and High-frequency Epr Ft-ir And Nmr Spectromentioning