1995
DOI: 10.1016/0924-4247(96)80088-4
|View full text |Cite
|
Sign up to set email alerts
|

A bidirectional silicon micropump

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
185
0
1

Year Published

1998
1998
2014
2014

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 292 publications
(187 citation statements)
references
References 7 publications
1
185
0
1
Order By: Relevance
“…The success of electrophoresis in microchannels for genomics has been a spectacular example [65]. Investigators have capitalized on continuing innovations in microfabrication to develop individual microfluidic components such as valves and pumps as well as diverse microsensors that operate in microchannels or microwells [57,58,[66][67][68][69][70][71][72][73][74][75][76][77] and several microscale active and passive flow regulators have been described [78][79][80][81].…”
Section: Adaptation For Chronic Perfusionmentioning
confidence: 99%
“…The success of electrophoresis in microchannels for genomics has been a spectacular example [65]. Investigators have capitalized on continuing innovations in microfabrication to develop individual microfluidic components such as valves and pumps as well as diverse microsensors that operate in microchannels or microwells [57,58,[66][67][68][69][70][71][72][73][74][75][76][77] and several microscale active and passive flow regulators have been described [78][79][80][81].…”
Section: Adaptation For Chronic Perfusionmentioning
confidence: 99%
“…Other types of pumps such as piezoelectric diaphragm [6][7][8], capillary pumps [35], electroosmotic pumps [36] and evaporation/condensation bubble pumps [37], have a very wide range of f sp value from 10 influenced by pumping principle rather than package size as also investigated in a past micropump review [4]. In these pumps, the developed pump is just placed in the moderate level not specially high or low.…”
Section: Performance Comparison With Other Micropumps On Chipmentioning
confidence: 99%
“…From the viewpoint of driving source, piezoelectric actuator has been frequently used [6][7][8]. Silicon, metal, or polymer components are the most common materials used in these pumps.…”
Section: Introductionmentioning
confidence: 99%
“…After the initial work at the University of Twente, other groups optimized [22,23] or modified [24] piezoelectric actuated micropumps and probably the most advanced micropump to date is the bi-directional one presented by Zengerle et al [25]. This pump uses an external piezo-actuator and has a complex, actuation frequency dependent mode of operation which creates bi-directional pumping as a function of frequency.…”
Section: Piezoelectric Actuationmentioning
confidence: 99%