2017
DOI: 10.1109/jssc.2017.2720636
|View full text |Cite
|
Sign up to set email alerts
|

A 950 nW Analog-Based Data Reduction Chip for Wearable EEG Systems in Epilepsy

Abstract: Long-term EEG monitoring is an important tool used for the diagnosis of epilepsy. Truly Wearable EEG can be considered as the future of ambulatory EEG units, which are the current standard for long-term EEG monitoring. Replacing these short lifetime, bulky units with long-lasting miniature and wearable devices which can easily be worn by patients will result in more EEG data being acquired for longer monitoring periods. This paper presents an analog based data reduction integrated circuit that would reduce the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
17
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(18 citation statements)
references
References 33 publications
1
17
0
Order By: Relevance
“…. , n) in (6) are determined values calculated by Maclaurin series expansion shown as (7). And so, the stability of approximated transfer function depends strongly upon the inter-relationship between wavelet scale, time delay and filter order.…”
Section: H a (S)mentioning
confidence: 99%
See 2 more Smart Citations
“…. , n) in (6) are determined values calculated by Maclaurin series expansion shown as (7). And so, the stability of approximated transfer function depends strongly upon the inter-relationship between wavelet scale, time delay and filter order.…”
Section: H a (S)mentioning
confidence: 99%
“…. ., 7) are searched within the bounds of (0,10), initial population size is 100, selection operator is tournament, crossover and mutation operators are arithmetic with probability of 0.8 and adaptive method, respectively.…”
Section: Design Example Of Analog Marr Wavelet Base Using Hybrid Gamentioning
confidence: 99%
See 1 more Smart Citation
“…And the chip with total area occupancy of 0.008mm 2 is achieved. In [13], a 950nW analog-based data reduction chip is proposed. And the low power consumption makes it more suitable for the application in wearable Electroencephalograph (EEG).…”
Section: Introductionmentioning
confidence: 99%
“…Taking these issues into account, in this paper, the continuous wavelet transform is implemented in an integrated low-power Gm-C filter, which is well suited for the application in wearable devices. Actually, the conception of integrated analog implementation of the continuous wavelet transform for the application in wearable devices has been studied by some previous works, such as [13], [21], [20]. However, in this paper, we pay more attention to the accuracy of the analog implementation of the wavelet transform.…”
Section: Introductionmentioning
confidence: 99%