2017 IEEE International Conference on Robotics and Automation (ICRA) 2017
DOI: 10.1109/icra.2017.7989062
|View full text |Cite
|
Sign up to set email alerts
|

A 3 wire body weight support system for a large treadmill

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
0
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 23 publications
0
0
0
Order By: Relevance
“…The conventional BWS to partially offload the user's weight generally used a single wire (Hidler et al, 2011), even for BWSOWT (Hidler et al, 2011), as displayed in Figure 2A. Since the unloading force generated by this method is very sensitive to the direction of the wire, several studies attempted to use three wires (Sabetian and Hollerbach, 2017), or four wires (Vallery et al, 2013) to improve the quality of unloading force (Figures 2B, C). However, those methods required large workspace and high cost, so are not appropriate to the approach to BWSOWT.…”
Section: Two Wire-driven Body Weight Support Mechanismmentioning
confidence: 99%
See 3 more Smart Citations
“…The conventional BWS to partially offload the user's weight generally used a single wire (Hidler et al, 2011), even for BWSOWT (Hidler et al, 2011), as displayed in Figure 2A. Since the unloading force generated by this method is very sensitive to the direction of the wire, several studies attempted to use three wires (Sabetian and Hollerbach, 2017), or four wires (Vallery et al, 2013) to improve the quality of unloading force (Figures 2B, C). However, those methods required large workspace and high cost, so are not appropriate to the approach to BWSOWT.…”
Section: Two Wire-driven Body Weight Support Mechanismmentioning
confidence: 99%
“…Most BWSs have used an overhead-type harness to provide unloading force (Koenig et al, 2009;Hidler et al, 2011;Vallery et al, 2013;Sabetian and Hollerbach, 2017), but we opted for pelvic-type harness (Figure 5A), because it is beneficial (1) to reduce the height (volume) of our BWS, and (2) to relieve the pendulum effect, due to its short distance between the acting point of the unloading force and the user's center of mass (Wyss et al, 2014).…”
Section: Pelvic-type Harnessmentioning
confidence: 99%
See 2 more Smart Citations
“…Simulated tripping has been performed on a treadmill to observe recovery motion [14][15][16]. Gait speed can be controlled on a treadmill more easily than in a walking lane.…”
Section: Introductionmentioning
confidence: 99%