Abstract: The procedure based on commercially available 96-well microfilter plates is shown to be useful for determining logP of ionized drugs in a rapid and efficient way.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
35
0

Year Published

2007
2007
2018
2018

Publication Types

Select...
8
2

Relationship

2
8

Authors

Journals

citations
Cited by 48 publications
(36 citation statements)
references
References 22 publications
1
35
0
Order By: Relevance
“…8 [57]. Ulmeanu et al used cyclic voltammetry and pH profiling to determine the partition coefficient of drugs using a commercial 96-well micro-filter plate system, which by nature requires only a small amount of the organic solvent and studied drug [58]. Other reports made significant contribution to the polarised membrane research, albeit not directly studying pharmaceutically relevant molecules [59][60][61][62][63].…”
Section: Voltammetry In Membrane Permeability Studiesmentioning
confidence: 99%
“…8 [57]. Ulmeanu et al used cyclic voltammetry and pH profiling to determine the partition coefficient of drugs using a commercial 96-well micro-filter plate system, which by nature requires only a small amount of the organic solvent and studied drug [58]. Other reports made significant contribution to the polarised membrane research, albeit not directly studying pharmaceutically relevant molecules [59][60][61][62][63].…”
Section: Voltammetry In Membrane Permeability Studiesmentioning
confidence: 99%
“…Girault et al [30] developed a new electrochemical method for lipophilicity determination based on a liquid layer immobilized between two aqueous compartments. The method was found to be a successful tool for drug partition coefficient determinations across several water-organic phase interfaces, for example, for the monobase tetramethylaniline and the monoacid dinitrophenol.…”
Section: N O T F O R D I S T R I B U T I O Nmentioning
confidence: 99%
“…The interfaces nitrobenzene/water, as well as 1,2-dichloroethane/water are good models for biological membranes, since they enable the rapid and precise determination of the electrochemical properties of ionised biological molecules. Both interfaces have already been used to probe the transfer of ionic drug compounds [14][15][16][17][18].…”