9.1 A Current-Sensing Front-End Realized by A Continuous-Time Incremental ADC with 12b SAR Quantizer and Reset-Then-Open Resistive DAC Achieving 140dB DR and 8ppm INL at 4kS/s

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 29 publications
(7 citation statements)
references
References 4 publications
0
7
0
Order By: Relevance
“…This calibration also compensates the AAF and ADC gain variability. In line with the measurement required for the EGOFET transfer curve acquisition, and matching most biosensor application requirements, the SNR has been measured using DC input currents [28]. The same approach has also been adopted in [29] where the DR is calculated with DC signals.…”
Section: B Cmos Si-ic Measurementsmentioning
confidence: 99%
See 2 more Smart Citations
“…This calibration also compensates the AAF and ADC gain variability. In line with the measurement required for the EGOFET transfer curve acquisition, and matching most biosensor application requirements, the SNR has been measured using DC input currents [28]. The same approach has also been adopted in [29] where the DR is calculated with DC signals.…”
Section: B Cmos Si-ic Measurementsmentioning
confidence: 99%
“…From Fig. 12(b) a DC dynamic range of 137 dB, defined as ratio between the largest input signal and the smallest that ensures an SNR>0 dB ( [28], [30]), can be extracted. It should be noted that this level of performance is not strictly needed for the single molecule detection procedure, for which an accurate estimation of the threshold is sufficient, but is useful for a research system as the one built in this work.…”
Section: B Cmos Si-ic Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“…Till now, CMOS current readout is the most creditable technique used in bio-sensing systems, such as photoplethysmography monitoring, molecular-concentration detection, and bioluminescent protein sensing, etc. [1]. As an example, some of the most used biosensors are shown in Fig.…”
Section: Introductionmentioning
confidence: 99%
“…Similarly, with high temperature the AC/DC ratio is increases significantly. Considering all the above mention challenges associated with the PPG sensors, in the recent past, many researchers have dedicated their effoert to developed a long time continuous and accurate measurement of the bio sign using the PPG devices (Wu et al 2020;Marefat et al 2020;Lin et al 2019). Khan et al (2019) proposed a flexible organic sensor for the health monitoring.…”
Section: Introductionmentioning
confidence: 99%