2020
DOI: 10.1007/s00542-020-05106-y
|View full text |Cite
|
Sign up to set email alerts
|

External temperature sensor assisted a new low power photoplethysmography readout system for accurate measurement of the bio-signs

Abstract: This study presents an external temperature sensor assisted a new low power, time-interleave, wide dynamic range, and low DC drift photoplethysmography (PPG) signal acquisition system to obtain the accurate measurement of various bio signs in real-time. The designed chip incorporates a 2-bit control programmable transimpedance amplifier (TIA), a high order filter, a 3:8 programmable gain amplifier (PGA) and 2 9 2 organic light-emitting diode (OLED) driver. Temperature sensor is used herein to compensate the ad… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 31 publications
0
2
0
Order By: Relevance
“…The process flow of the digital control and quality assessment unit is shown in Fig. 3, which comprised a moving average filtering, peak-through detection, periodicity check, amplitude check, power spectrum (PS) check, OLED array control and PGA gain control [18]. To implement this, a 4:1 analog multiplexer is designed in the AFE and the 2-bit select signal is used to turn ON the OLED one-by-one for 3 seconds.…”
Section: Digital Control Unit Quality Assessment Algorithm and Heart Rate Measurementmentioning
confidence: 99%
See 1 more Smart Citation
“…The process flow of the digital control and quality assessment unit is shown in Fig. 3, which comprised a moving average filtering, peak-through detection, periodicity check, amplitude check, power spectrum (PS) check, OLED array control and PGA gain control [18]. To implement this, a 4:1 analog multiplexer is designed in the AFE and the 2-bit select signal is used to turn ON the OLED one-by-one for 3 seconds.…”
Section: Digital Control Unit Quality Assessment Algorithm and Heart Rate Measurementmentioning
confidence: 99%
“…The algorithm for the heart rate estimation is shown in 3 (b). The raw PPG signal will be filtered by the convolution filter [18], then the peak-peak interval/pulse repetition time (PRT) is measured to estimate the HR in the time domain. Also, the frequency (FHR) of the first harmonics of the single sided spectrum (Fig 3(c…”
Section: Digital Control Unit Quality Assessment Algorithm and Heart Rate Measurementmentioning
confidence: 99%