2015
DOI: 10.1016/j.ijrobp.2014.09.043
|View full text |Cite
|
Sign up to set email alerts
|

4π Noncoplanar Stereotactic Body Radiation Therapy for Head-and-Neck Cancer: Potential to Improve Tumor Control and Late Toxicity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
76
0
1

Year Published

2017
2017
2020
2020

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 67 publications
(80 citation statements)
references
References 38 publications
3
76
0
1
Order By: Relevance
“…Collisions between the treatment hardware and the patient continue to present a challenge concerning patient safety and equipment damage in radiotherapy. Additionally, the lack of reliable collision avoidance is a critical barrier to the delivery of advanced trajectory treatments in the future . While accurate collision detection and avoidance in radiotherapy has been investigated in different forms over the last few decades, a solid clinical implementation has not been widely adopted across the community.…”
Section: Introductionmentioning
confidence: 99%
“…Collisions between the treatment hardware and the patient continue to present a challenge concerning patient safety and equipment damage in radiotherapy. Additionally, the lack of reliable collision avoidance is a critical barrier to the delivery of advanced trajectory treatments in the future . While accurate collision detection and avoidance in radiotherapy has been investigated in different forms over the last few decades, a solid clinical implementation has not been widely adopted across the community.…”
Section: Introductionmentioning
confidence: 99%
“…The DNN learns its behavior from the full implementation of one iteration of CG, the CP‐DL‐ST processes; therefore, the DNN also tries to predict the best beam orientation that can be added to the current state of the problem. Note that as a greedy algorithm, CG does not guarantee global optimality, but it has been shown to produce superior results for treatment planning problems in existing literature …”
Section: Discussionmentioning
confidence: 99%
“…Although it is not fully clear what the acceptable error margins are for clinical acceptance. CG already outperforms manually beam selected plans . Also, for these to be used in the clinic, the dosimetrist will be going through many trial‐and‐error iterations to obtain an acceptable plan.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The original investigations published provided evidence of benefit and proof of principle for smaller tumors. A study involving the 4 π approach to SF‐IMRT for HNC was also attempted but it was for small and recurrent cancers 16. The question of applicability of 4 π techniques to truly large target volumes and its feasibility for conventional IMRT/VMAT treatments remains unaddressed for HNC.…”
Section: Introductionmentioning
confidence: 99%