2010
DOI: 10.1109/tuffc.2010.1688
|View full text |Cite
|
Sign up to set email alerts
|

4-D x 3-D ultrasound: real-time scan conversion, filtering, and display of displacement vectors with a motorized curvilinear transducer

Abstract: Recent research in the field of elastography has sought to expand displacement tracking to three dimensions. Once the 3-D volumes of displacement data have been obtained, they must be scan converted so that further processing, such as inversion methods to obtain tissue elasticity, can take place in Cartesian coordinates. This paper details an efficient and geometrically accurate algorithm to scan convert 3-D volumes of displacement vectors obtained from a motorized sector transducer. The proposed algorithm uti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 24 publications
0
5
0
Order By: Relevance
“…Despite a clear outline of the procedure, SC lacks methodology and remains cumbersome to perform. Reported implementations are actually transducer specific [19] as, for instance, there is no systematic and automatic way to derive the coordinate system transformation regardless of the used probe. Thanks to our expertise as roboticists, we propose in the following sections an adequate method for implementing SC that is not only meant to be straightforward for the nonspecialist reader but also can be extended to any transducer geometry.…”
Section: B Reconstruction Proceduresmentioning
confidence: 99%
See 2 more Smart Citations
“…Despite a clear outline of the procedure, SC lacks methodology and remains cumbersome to perform. Reported implementations are actually transducer specific [19] as, for instance, there is no systematic and automatic way to derive the coordinate system transformation regardless of the used probe. Thanks to our expertise as roboticists, we propose in the following sections an adequate method for implementing SC that is not only meant to be straightforward for the nonspecialist reader but also can be extended to any transducer geometry.…”
Section: B Reconstruction Proceduresmentioning
confidence: 99%
“…Correctness of reconstructed volume's geometry measurement: Beyond assessing the resolution of the 2D B-mode images, this paper also aims to quantitatively evaluate the correctness of volumetric reconstruction since this new imaging platform is meant for medical purposes. To the best of the authors' knowledge, there is no agreed standard in the literature, and existing works on SC actually rely only on visual inspection for validation [17]- [19]. The only paper that presents such a quantitative test is a freehand US related work [31].…”
Section: Evaluation Of System Performancesmentioning
confidence: 99%
See 1 more Smart Citation
“…A large group of commercial 3D ultrasound imaging systems employs motorized curvilinear probes (Pospisil et al, 2010;Gao et al, 2016). Hence, 3D motorized curvilinear probes provide an attractive means to enable 3D ultrasound guidance of needle insertion interventions.…”
Section: A C C E P T E D Mmentioning
confidence: 99%
“…In many applications, especially those with ultrasound as the imaging modality, only two components of the displacements are available in a single plane and the inverse problem has to be solved for the unknown elasticity parameters within that plane. Since most ultrasound machines provide 2D images of the tissue, it is difficult to obtain 3D displacement maps with a high accuracy in the out-of-plane direction (Pospisil et al 2010). The objective, here, is to use the measured 2D displacements in a single plane to reconstruct the distribution of the mechanical parameters, such as Young's modulus.…”
Section: Introductionmentioning
confidence: 99%