2017 IEEE International Ultrasonics Symposium (IUS) 2017
DOI: 10.1109/ultsym.2017.8091946
|View full text |Cite
|
Sign up to set email alerts
|

3D ultrasound palm vein recognition through the centroid method for biometric purposes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
4
1
1

Relationship

2
4

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 11 publications
0
6
0
Order By: Relevance
“…The proposed approach has the further merit of being able to automatically detect the liveness of the sample by checking vein pulsing during image acquisition, which makes it very difficult to spoof. Furthermore, the same volumetric image can be exploited for extracting other 3-D palmprint features through curvature methods [34] as well as other features than palmprint like inner hand geometry [66], hand geometry [67], [68] and vein pattern [69], [70], implementing in this way a hand-based multimodal system, which is expected to improve the overall performances of the system.…”
Section: Discussionmentioning
confidence: 99%
“…The proposed approach has the further merit of being able to automatically detect the liveness of the sample by checking vein pulsing during image acquisition, which makes it very difficult to spoof. Furthermore, the same volumetric image can be exploited for extracting other 3-D palmprint features through curvature methods [34] as well as other features than palmprint like inner hand geometry [66], hand geometry [67], [68] and vein pattern [69], [70], implementing in this way a hand-based multimodal system, which is expected to improve the overall performances of the system.…”
Section: Discussionmentioning
confidence: 99%
“…The next operation is binarization. In previous works [37,38], a global threshold was set based on heuristic considerations. However, this approach is suitable only if images under analysis have more or less the same characteristics in terms of illumination and contrast.…”
Section: Feature Extractionmentioning
confidence: 99%
“…Blue illumination enhances the skin surface structure, whereas far‐red and infra‐red mainly show the vein structure. Antonio [21] used a commercial ultrasound imaging machine to capture the 3D palm vein pattern. Wang [22] gets deep information of the palm vessel through a 3‐D image of palm vasculature.…”
Section: Palm Vein Image Acquisitionmentioning
confidence: 99%