2011
DOI: 10.2463/mrms.10.29
|View full text |Cite
|
Sign up to set email alerts
|

3D MR Cisternography to Identify Distal Dural Rings: Comparison of 3D-CISS and 3D-SPACE Sequences

Abstract: Purpose: The distal dural ring (DDR) is an anatomical landmark used to distinguish intra-and extradural aneurysms. We investigated identiˆcation of the DDR using 2 threedimensional (3D) magnetic resonance (MR) cisternography sequences-3D constructive interference in steady state (CISS) and 3D sampling perfection with application optimized contrasts using diŠerent ‰ip angle evolutions (SPACE)-at 3.0 tesla.Methods: Ten healthy adult volunteers underwent imaging with 3D-CISS, 3D-SPACE, and time-of-‰ight (TOF) MR … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
13
0
1

Year Published

2011
2011
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(14 citation statements)
references
References 7 publications
0
13
0
1
Order By: Relevance
“…3,6,16 However, these techniques have their own advantages and disadvantages. 5,19,20 For instance, PC-MRI can provide physiologic information about CSF flow; however, it might fail in case of complex flow or vascular pulsations.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…3,6,16 However, these techniques have their own advantages and disadvantages. 5,19,20 For instance, PC-MRI can provide physiologic information about CSF flow; however, it might fail in case of complex flow or vascular pulsations.…”
Section: Discussionmentioning
confidence: 99%
“…With this flexible sequence; T1-weighted, T2-weighted, proton-attenuation, or FLAIR images can be obtained. 20 The advantages of the 3D-SPACE sequence in evaluation of the spine, pelvis, and abdomen have been reported previously. 8,12 3D-SPACE sequence uses different flip angles, which enable a low specific absorption rate value, therefore obtaining good T2-weighted images.…”
mentioning
confidence: 99%
“…[7][8][9][10] High contrast-to-noise ratio, multiplanar evaluation of volumetric data, and thin-section image acquisition are the main advantages of NCE-MRC. 11 Moreover, it is noninvasive, and it does not require radiation exposure or intrathecal contrast material administration. 4 Although NCE-MRC has several advantages, it can only provide morphologic information different from that in other cisternographic studies.…”
mentioning
confidence: 99%
“…Intrathecal Gd injection is not approved by the FDA, though its safety has been reported in several pilot studies in Europe. [2][3][4]6,[9][10][11][12][13][14] Tolerance and dose limits of intrathecal Gd injection were established in animal model studies, and different Gd compounds (eg, gadodiamide, gadobenate dimeglumine, and Gd-DTPA) were compared in different experimental animal protocols. 5,[14][15][16][17] High-dose intraventricular Gd injection was reported to result in behavioral and neurologic disturbances (focal seizures, ataxia, latent tremor) with histopathologic changes (loss of oligodendroglia, astrocytic hypertrophy, and eosinophilia); on the other hand, it was concluded that these changes and distur-bance did not occur if the total injected dose wasϽ15 mL (3.3 mmol/g).…”
mentioning
confidence: 99%
“…For MRI, imaging methods using the fusion of noncontrast and the contrast interference in steady state (CISS) method and MRA, contrasted 3D-MRA, and contrasted 3D-CISS have been reported. Additionally, studies of 3D-SPACE (sampling perfection with applicationoptimized contrast using different flip angle evolutions) sequences, T2 turbo-spin echo sequences, and noncontrasted 3D time-of-flight (TOF) by 3T MRI with high signal-to-noise (S/N) ratios have been conducted [16][17][18][19][20]. However, these imaging methods show the DDR indirectly.…”
Section: Discussionmentioning
confidence: 96%