Image similarity‐based cardiac rhythm device identification from X‐rays using feature point matching

Abstract: Aims Identifying the manufacturer and the type of cardiac implantable electronic devices (CIEDs) is important in emergent clinical settings. Recent studies have illustrated that artificial neural network models can successfully recognize CIEDs from chest X‐ray images. However, all existing methods require a vast amount of medical data to train the classification model. Here, we have proposed a novel method to retrieve an identical CIED image from an image database by employing the feature point matching algori… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 17 publications
0
6
0
Order By: Relevance
“…Computer vision technology can derive a lot of information from simple chest X-ray images [ 8 ]. In this technical report, we have demonstrated a proof-of-concept that the trajectory of the right ventricular pacemaker lead could be reconstructed from chest radiography taken at 90-degree angles.…”
Section: Discussionmentioning
confidence: 99%
“…Computer vision technology can derive a lot of information from simple chest X-ray images [ 8 ]. In this technical report, we have demonstrated a proof-of-concept that the trajectory of the right ventricular pacemaker lead could be reconstructed from chest radiography taken at 90-degree angles.…”
Section: Discussionmentioning
confidence: 99%
“…Alternatively, the device identification card can be used to obtain information from the manufacturer’s website or calling the “help line.” These resources can also be used to obtain advice regarding specific perioperative management, such as the need for preoperative programming and response to magnet placement. 12…”
Section: Pros Of An Asc Setting For a Patient With A Ciedmentioning
confidence: 99%
“…These resources can also be used to obtain advice regarding specific perioperative management, such as the need for preoperative programming and response to magnet placement. 12 Adequate functioning of the CIED must be confirmed before surgery. 8 It is recommended that CIEDs, particularly ICDs, should be interrogated within 30 days before the surgical procedure.…”
Section: Pros Of An Asc Setting For a Patient With A Cied Preoperativ...mentioning
confidence: 99%
“…The semantic similarity-based image similarity calculation gets some basic information [5] about the image for comparison by linking the image spatial context and situational context; it is a high-level linkage of image target entities with a high level of abstraction and immature theory. The expense of converting one graph into another graph is calculated, i.e., predefining the set of operations for various transformations and defining the minimum change step between two graphs as the similarity of the two graphs, i.e., the image edit distance [6].…”
Section: Related Workmentioning
confidence: 99%