2022
DOI: 10.1109/tuffc.2022.3145162
|View full text |Cite
|
Sign up to set email alerts
|

3-D High Frequency Ultrasound Imaging by Piezo-Driving a Single-Element Transducer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
2
1

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 49 publications
0
5
0
Order By: Relevance
“…Test results showed that CMPCs-driven scanner requires a lower voltage and smaller size, especially in the axial dimension, to achieve comparable performance to the piezo tube-driven structure. The size of the piezo tube as actuator in Reference [ 4 ] is Φ7 × 35 mm; the size of the CMPCs parts in this work is only 5 mm × 5 mm × 13 mm, which is 22 mm shorter in axial dimensions in comparison. As the natural frequency increased, the vibration velocity increased and was subjected to increased damping force, which led to a decrease in amplitude.…”
Section: Experimental Testingmentioning
confidence: 96%
See 1 more Smart Citation
“…Test results showed that CMPCs-driven scanner requires a lower voltage and smaller size, especially in the axial dimension, to achieve comparable performance to the piezo tube-driven structure. The size of the piezo tube as actuator in Reference [ 4 ] is Φ7 × 35 mm; the size of the CMPCs parts in this work is only 5 mm × 5 mm × 13 mm, which is 22 mm shorter in axial dimensions in comparison. As the natural frequency increased, the vibration velocity increased and was subjected to increased damping force, which led to a decrease in amplitude.…”
Section: Experimental Testingmentioning
confidence: 96%
“…According to the driving method, optical scanners are primarily classified into mechanical, galvanometric, electronic, micro-electro–mechanical systems (MEMS), piezoelectric systems, etc. [ 1 , 2 , 3 , 4 , 5 ]. Currently, the most used mechanical optical scanners cannot easily meet the requirements of large angles, low errors, or high-speed scanning.…”
Section: Introductionmentioning
confidence: 99%
“…PRI, which is the time interval between two adjacent emitting pulses, is normally fixed value and can be adjusted to change the spatial sampling rate. The smaller the PRI, the higher the spatial sampling rate [19]. However, reaching a sufficient spatial sampling rate with a smaller PRI does not continue to improve the ultrasound image quality, but rather causes an increase in data volume.…”
Section: Working Characteristicsmentioning
confidence: 99%
“…The center frequency, bandwidth and dynamic performance of the transducer prototype for ultrasound imaging were evaluated. The pulse-echo method was utilized to characterize the center frequency and bandwidth of the ultrasound transducer (see [19] for more details). According to the pulse-echo testing, the center frequency of the ultrasound transducer is The frequency-domain response measurement is to obtain the relationship between the scanner amplitude and the excitation signal frequency.…”
Section: Performance Evaluationmentioning
confidence: 99%
See 1 more Smart Citation