2010
DOI: 10.1016/j.talanta.2010.04.048
|View full text |Cite
|
Sign up to set email alerts
|

2D spatiotemporal visualization system of expired gaseous ethanol after oral administration for real-time illustrated analysis of alcohol metabolism

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
4
2
1

Relationship

2
5

Authors

Journals

citations
Cited by 19 publications
(9 citation statements)
references
References 31 publications
0
9
0
Order By: Relevance
“…29 The enzyme/PVA-SbQ mixture was coated onto the support, spread, cured and treated with ultraviolet irradiation. 28 Enzyme-immobilized supports were stored at 4 C before use. A comparison between the mesh supports and the H-PTFE supports was carried out and the effect of concentration of luminol was investigated in the range 1.0-15.0 mM under the experimental conditions: [Tris-HCl buffer solution]…”
Section: Evaluation Of the Spatial Visualization Systemmentioning
confidence: 99%
See 2 more Smart Citations
“…29 The enzyme/PVA-SbQ mixture was coated onto the support, spread, cured and treated with ultraviolet irradiation. 28 Enzyme-immobilized supports were stored at 4 C before use. A comparison between the mesh supports and the H-PTFE supports was carried out and the effect of concentration of luminol was investigated in the range 1.0-15.0 mM under the experimental conditions: [Tris-HCl buffer solution]…”
Section: Evaluation Of the Spatial Visualization Systemmentioning
confidence: 99%
“…For this reason, the comparisons between the mesh supports and the H-PTFE membrane supports were performed by calibration plots in the previous study. 28 The average CL intensity, calibration range and sensitivity were compared. The peak of average CL intensities within the enzyme-immobilized area obtained from the mesh support was higher than the ones from the H-PTFE membrane support, which is mainly because the amount of HRP immobilized on the mesh support was more than that on the H-PTFE membrane support.…”
Section: Evaluation Of the Spatial Visualization Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…Many sensor technologies employing enzymatic reactions have been developed, such as bio‐sniffers (biochemical gas sensors) for gaseous chemicals ethanol, acetaldehyde (alcohol metabolism), trimethylamine (fish‐odor syndrome), methylmercaptan (halitosis), acetone (diabetes, lipid metabolism) . Authors also developed an imaging system of gaseous ethanol based on bio‐chemiluminescence and bio‐fluorescence measurement employing an EM‐CCD camera for imaging of body gaseous chemicals in breath air and transdermal human gas .…”
Section: Introductionmentioning
confidence: 99%
“…In another application, the data from a network of chemical sensors were fused with tracking data from video systems for the detection of hazardous material released from moving sources [27]. Recently, chemical methods were applied in combination with a chargecoupled device (CCD) camera for real time analysis of ethanol in expired air [28].…”
Section: Introductionmentioning
confidence: 99%