2018
DOI: 10.1093/ejo/cjy006
|View full text |Cite
|
Sign up to set email alerts
|

Transfer accuracy of two indirect bonding techniques—an in vitro study with 3D scanned models

Abstract: Although both transfer methods showed a high precision, silicone trays scored better in terms of accuracy than double-vacuum forms.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

16
85
1
6

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 51 publications
(108 citation statements)
references
References 8 publications
16
85
1
6
Order By: Relevance
“…With the advance of digital technology, 3D assessment using the scanned model has been proposed to be more accurate than 2D assessment using digital photography. 5,[13][14][15]18 In this study, a semiautomated 3D measurement in Geomagic Studio 2013 was used to measure the position and orientation deviations for 205 brackets. Because the local coordinate system had been prelocated on the bracket, there was no need to identify the corresponding reference points on the teeth from different patients repeatedly.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…With the advance of digital technology, 3D assessment using the scanned model has been proposed to be more accurate than 2D assessment using digital photography. 5,[13][14][15]18 In this study, a semiautomated 3D measurement in Geomagic Studio 2013 was used to measure the position and orientation deviations for 205 brackets. Because the local coordinate system had been prelocated on the bracket, there was no need to identify the corresponding reference points on the teeth from different patients repeatedly.…”
Section: Discussionmentioning
confidence: 99%
“…The sample size was determined according to previous studies. 5,15 With an observed sample size of n 5 205, a power analysis for Wilcoxon matched-pairs signed rank test (2-tailed) conducted a posteriori using G*Power 3.1.9.3 indicated 100% power to detect a small effect size (Cohen's d 5 0.4) at a significance level of 0.05.…”
Section: Statistic Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…When comparing the groups with respect to operator experience, experienced clinicians committed a lower percentage of errors in the angular dimension. The results of errors that exceeded the clinical limit were reported in relation to the types of guides 13,21 and influence of the cusp height of posterior teeth, 10 but they have not been specific about the positioning of the attachments.…”
Section: Discussionmentioning
confidence: 99%
“…Additionally, all the solid cast models were prototyped with the same type of resin and scanned with a single scanner. 20,21 The methods for measuring the positions of the orthodontic attachments have improved over time. Most recently, the use of superimposed three-dimensional (3D) images with cone beam computed tomography incorporated a new level of precision into analyses.…”
Section: Discussionmentioning
confidence: 99%