2017
DOI: 10.1002/jmri.25890
|View full text |Cite
|
Sign up to set email alerts
|

Mapping brown adipose tissue based on fat water fraction provided by Z‐spectral imaging

Abstract: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:1527-1533.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
24
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 14 publications
(26 citation statements)
references
References 35 publications
(73 reference statements)
2
24
0
Order By: Relevance
“…Body composition was assessed by magnetic resonance imaging (MRI) scan on gestational day 18. Mice were anesthetized with vaporized isoflurane (1.5%) to reduce respiratory motion artifacts and then imaged on a 3.0‐T MRI system (Magnetom Verio; Siemens, Erlangen, Germany) with an eight‐channel wrist coil as previously described . The volumes of the abdominal visceral WAT (vWAT, containing the perigonadal WAT [pWAT]) and subcutaneous WAT (scWAT, containing the inguinal WAT [iWAT]) were calculated for transverse sections via a manual threshold setting in ImageJ 1.41 (National Institutes of Health, Bethesda, Maryland).…”
Section: Methodsmentioning
confidence: 99%
“…Body composition was assessed by magnetic resonance imaging (MRI) scan on gestational day 18. Mice were anesthetized with vaporized isoflurane (1.5%) to reduce respiratory motion artifacts and then imaged on a 3.0‐T MRI system (Magnetom Verio; Siemens, Erlangen, Germany) with an eight‐channel wrist coil as previously described . The volumes of the abdominal visceral WAT (vWAT, containing the perigonadal WAT [pWAT]) and subcutaneous WAT (scWAT, containing the inguinal WAT [iWAT]) were calculated for transverse sections via a manual threshold setting in ImageJ 1.41 (National Institutes of Health, Bethesda, Maryland).…”
Section: Methodsmentioning
confidence: 99%
“…Compared to PET and SPECT, MR imaging is a more attractive modality for human studies due to no ionizing-radiation. In recent years, developing MRI methods that can differentiate BAT and WAT has been an increasing interest [127][128][129][130]. The unique structure of BAT with multilocular oil droplets and dense mitochondria and abundant capillaries provides a unique basis for MRI to selectively image BAT via different mechanisms of generating image contrast.…”
Section: Magnetic Resonance Imaging (Mri)mentioning
confidence: 99%
“…Signal intensity as a function of saturation frequency is then used to obtain a Z-spectrum from which water and fat signal components can be extracted, on a voxel-by-voxel basis. This method was initially tested in excised BAT samples and in vivo in humans (73), and later implemented to measure temperature in a water-fat emulsion phantom (74). With this method, the phase of the MR signal is completely ignored, so there are no phase distortions, and no assumption is made on the relative water-fat frequency, which is known to be greatly affected by microscopic field inhomogeneities in supraclavicular fat (69).…”
Section: Z-spectrum Imaging [Recently Proposed Technique]mentioning
confidence: 99%