2017
DOI: 10.1016/j.joen.2017.02.005
|View full text |Cite
|
Sign up to set email alerts
|

Effect of ProTaper Gold, Self-Adjusting File, and XP-endo Shaper Instruments on Dentinal Microcrack Formation: A Micro–computed Tomographic Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

5
81
0
8

Year Published

2017
2017
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 78 publications
(103 citation statements)
references
References 20 publications
5
81
0
8
Order By: Relevance
“…This is in agreement with previous micro-CT investigations (5,15) and may be related to the higher resolution and magnification of micro-CT images compared with stereomicroscopy (7) which emphasises the importance of a reliable and non-destructive, three-dimensional technology for the analysis of microcrack formation (14). This is in agreement with previous micro-CT investigations (5,15) and may be related to the higher resolution and magnification of micro-CT images compared with stereomicroscopy (7) which emphasises the importance of a reliable and non-destructive, three-dimensional technology for the analysis of microcrack formation (14).…”
Section: Discussionsupporting
confidence: 94%
“…This is in agreement with previous micro-CT investigations (5,15) and may be related to the higher resolution and magnification of micro-CT images compared with stereomicroscopy (7) which emphasises the importance of a reliable and non-destructive, three-dimensional technology for the analysis of microcrack formation (14). This is in agreement with previous micro-CT investigations (5,15) and may be related to the higher resolution and magnification of micro-CT images compared with stereomicroscopy (7) which emphasises the importance of a reliable and non-destructive, three-dimensional technology for the analysis of microcrack formation (14).…”
Section: Discussionsupporting
confidence: 94%
“…There is only one study in the literature on the effect of XPS instruments on dentinal microcrack formation (Bayram, Bayram, Ocak, Uygun, & Celik, ). In this study, despite the use of mandibular incisors, the authors detected no new crack formation after root canal preparation.…”
Section: Discussionmentioning
confidence: 99%
“…, , Bayram et al . ) and precludes the need for sectioning specimens. This technology enables not only the visualization of pre‐existing dentinal defects but also their precise location throughout the root before and after fractured file removal, thus improving the internal validity of the experiment, considering that each specimen acts as its own control.…”
Section: Discussionmentioning
confidence: 99%