2017
DOI: 10.1016/j.chroma.2016.12.009
|View full text |Cite
|
Sign up to set email alerts
|

Sampling only ten microliters of whole blood for the quantification of poorly soluble drugs: Itraconazole as case study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 27 publications
(17 citation statements)
references
References 30 publications
0
17
0
Order By: Relevance
“…The hydrophilic tip is found at the end of a plastic handler that can be attached to automated sample processing systems. VAMS is successfully used today for pharmacokinetic and therapeutic drug monitoring studies both in animal and human experiments [15,16]. VAMS devices were created for their ability of remote blood sampling, easy transportation of collected dried blood samples without using special transportation equipment such as cold packs or dried ice, assuring analyte stability.…”
Section: Introductionmentioning
confidence: 99%
“…The hydrophilic tip is found at the end of a plastic handler that can be attached to automated sample processing systems. VAMS is successfully used today for pharmacokinetic and therapeutic drug monitoring studies both in animal and human experiments [15,16]. VAMS devices were created for their ability of remote blood sampling, easy transportation of collected dried blood samples without using special transportation equipment such as cold packs or dried ice, assuring analyte stability.…”
Section: Introductionmentioning
confidence: 99%
“…The Three Rs rule—replacement, reduction, and refinement—is a set of guiding principles for the more ethical use of animals in scientific study. Nowadays, complying with this rule is of utmost importance, and efforts must be made to enhance animal welfare (Thiry, Evrard, Nys, Fillet, & Kok, 2017). In this study, 20 μL of plasma was needed for sample preparation.…”
Section: Resultsmentioning
confidence: 99%
“…Quantification of itraconazole was possible by using only 10 μL of whole blood: the itraconazole was slightly affected by the matrix (91.2%), whereas there were slightly positive MEs observed for hydroxy-itraconazole (110.7%) [ 108 ]. When the sample dilution approach or injection of smaller volumes does not provide adequate solutions for overcoming MEs, sample preparation becomes compulsory to selectively eliminate or reduce co-eluting interferences.…”
Section: Minimizing Matrix Effectsmentioning
confidence: 99%