2016
DOI: 10.1097/shk.0000000000000464
|View full text |Cite
|
Sign up to set email alerts
|

Effect of External Pressure and Catheter Gauge on Flow Rate, Kinetic Energy, and Endothelial Injury During Intravenous Fluid Administration in a Rabbit Model

Abstract: The effects of intravenous (IV) catheter gauge and pressurization of IV fluid (IVF) bags on fluid flow rate have been studied. However, the pressure needed to achieve a flow rate equivalent to that of a 16 gauge (G) catheter through smaller G catheters and the potential for endothelial damage from the increased kinetic energy produced by higher pressurization are unclear. Constant pressure on an IVF bag was maintained by an automatic adjustable pneumatic pressure regulator of our own design. Fluids running thr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 25 publications
0
4
0
Order By: Relevance
“…Although pressure bags had a significant effect on flow rate, their use in clinical cases could be impractical if several 5-L fluid bags are hung at the same time, which is a common practice in hypovolemic large animal patients. 6 Also, the risk of endothelial damage secondary to the increase in pressure 22 was not evaluated in the present study, as well as the use of other pressure devices such as peristaltic pumps. These are interesting areas for further investigation.…”
Section: Discussionmentioning
confidence: 95%
“…Although pressure bags had a significant effect on flow rate, their use in clinical cases could be impractical if several 5-L fluid bags are hung at the same time, which is a common practice in hypovolemic large animal patients. 6 Also, the risk of endothelial damage secondary to the increase in pressure 22 was not evaluated in the present study, as well as the use of other pressure devices such as peristaltic pumps. These are interesting areas for further investigation.…”
Section: Discussionmentioning
confidence: 95%
“…9,10,11,12 The pressure used during infusion and the flow rate should also be taken into account. 23 Preventing I/E is one of the basic responsibilities of nurses. When the first symptoms of I/E are seen, IV fluid therapy should be stopped immediately, the IV set should be removed from the IV catheter, the residual IV fluid and medication therapy from the IV catheter should be aspirated, the IV fluid should be aspirated manually from the tissue, and the antidote for the infiltrated medication should be used.…”
Section: Discussionmentioning
confidence: 99%
“…9,10,11,12 The pressure used during infusion and the flow rate should also be taken into account. 23…”
Section: Discussionmentioning
confidence: 99%
“…Currently, one of the leading causes of death is trauma and 40% of trauma deaths are caused by bleeding [1]. Other situations where patients need to receive blood rapidly are when they have major blood loss from surgery, dehydration, or shock [2]. Massive blood loss requires rapid resuscitation.…”
Section: Introductionmentioning