Remote programming of cochlear implants

Abstract: DescritoresThe RP is a simple and effective procedure for programming cochlear implant devices and, although there were differences in the stimulation levels of some electrodes, it did not interfere in the speech perception outcomes. RESUMOObjetivo: verificar a efetividade da programação remota do implante coclear por meio dos níveis de estimulação e resultados nos testes de percepção de fala e audiometria em campo livre. Métodos: Foram selecionados 12 pacientes de ambos os gêneros, com idade entre 18 e 59 ano… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
2
0
5

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(7 citation statements)
references
References 16 publications
(54 reference statements)
0
2
0
5
Order By: Relevance
“…In their 2012 study, Hughes and colleagues (12) found no significant differences in electrode-specific measures (impedance, ECAP thresholds, and MAP levels) when tests were conducted remotely versus in-office. Samuel et al (13) compared remote and in-office programming sessions performed on a single user on the same day and found no significant differences in audiometric thresholds or speech perception scores. The participants in this study demonstrated some variations in stimulation levels when remote and in-office programming sessions were compared, however the authors concluded that providing CI programming services remotely is safe and effective.…”
Section: Introductionmentioning
confidence: 99%
“…In their 2012 study, Hughes and colleagues (12) found no significant differences in electrode-specific measures (impedance, ECAP thresholds, and MAP levels) when tests were conducted remotely versus in-office. Samuel et al (13) compared remote and in-office programming sessions performed on a single user on the same day and found no significant differences in audiometric thresholds or speech perception scores. The participants in this study demonstrated some variations in stimulation levels when remote and in-office programming sessions were compared, however the authors concluded that providing CI programming services remotely is safe and effective.…”
Section: Introductionmentioning
confidence: 99%
“…E um eletrodo na pesquisa dos níveis de estimulação máximos (níveis C), tendo a corrente menor na programação remota. Entretanto, para os resultados dos testes de percepção de fala e audiometria não foram observadas diferenças significativas nas duas modalidades de atendimento 23 .…”
Section: Discussionunclassified
“…Depuis 2010, la télémédecine s'est considérablement développée dans les domaines de l'audiologie et de l'orthophonie [17,18]. Cependant, la rééducation à distance des patients implantés cochléaires n'est pas encore très développée, et, en France, ne bénéficie pas à ce jour de cadre défini.…”
Section: Introductionunclassified