2014
DOI: 10.1016/j.radonc.2014.08.002
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of DVH-based treatment plan verification in addition to gamma passing rates for head and neck IMRT

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
34
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(34 citation statements)
references
References 21 publications
0
34
0
Order By: Relevance
“…Patient-specific pre-treatment quality assurance (QA) is necessary for the implementation of IMRT [3], and it has been a consensus of the researcher community that patient-specific QA can be done by film dosimetry combined with ionization chambers measurement [46], or by a 2D/3D detector arrays test in a phantom to compare and validate the dose accuracy of the treatment [7–10]. Most of these pre-treatment QA use the ‘γ evaluation method’ for the result analysis, which is a composite analysis of distance-to-agreement (DTA) and dose difference (DD) [1113]. …”
Section: Introductionmentioning
confidence: 99%
“…Patient-specific pre-treatment quality assurance (QA) is necessary for the implementation of IMRT [3], and it has been a consensus of the researcher community that patient-specific QA can be done by film dosimetry combined with ionization chambers measurement [46], or by a 2D/3D detector arrays test in a phantom to compare and validate the dose accuracy of the treatment [7–10]. Most of these pre-treatment QA use the ‘γ evaluation method’ for the result analysis, which is a composite analysis of distance-to-agreement (DTA) and dose difference (DD) [1113]. …”
Section: Introductionmentioning
confidence: 99%
“…(6) DVH-based quality assurance (hereafter referred to as the "Planned Dose Perturbation method" used in 3DVH (Sun Nuclear, Melbourne, FL)) has been discussed by various groups recently. (7)(8)(9)(10)(11)(12) Validations of this DVH-based QA have been performed by different researchers, proving that dose reconstructed via 3DVH is consistent with dose reconstructed through other detectors and algorithms. (6,(13)(14) Significant errors were discovered via DVH-based QA, where the GI/DTA methods did not find the errors, indicating potential pitfalls in using recommended GI/DTA metrics and action levels.…”
mentioning
confidence: 77%
“…DVH‐based quality assurance (hereafter referred to as the “Planned Dose Perturbation method” used in 3DVH (Sun Nuclear, Melbourne, FL)) has been discussed by various groups recently 7 , 8 , 9 , 10 , 11 , 12 . Validations of this DVH‐based QA have been performed by different researchers, proving that dose reconstructed via 3DVH is consistent with dose reconstructed through other detectors and algorithms 6 , 13 , 14 .…”
Section: Introductionmentioning
confidence: 87%
See 2 more Smart Citations