Successful endovascular extraction of newer generation Angio-Seal collagen plug and anchor after acute embolization

Abstract: A 75-year-old woman with past medical history of coronary bypass, atrial fibrillation, mitral valve repair undergoes percutaneous coronary intervention of left circumflex artery with a drug eluting stent. An Anglo-Seal vascular closure device was used post procedure to obtain hemostasis. Shortly after deployment, frank bleeding was observed necessitating manual compression at the arteriotomy site. After hemostasis was achieved, the right lower extremity was found to be pale, bluish with feeble pulses. Doppler … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 5 publications
(4 reference statements)
0
4
0
Order By: Relevance
“…There are previous reports of endovascular Angio-Seal removal, but these attempts have been complicated by difficult direct visualization, with partial retrieval or distal embolization following manipulation. 5,6 Rafeh et al describe a fluoroscopic guided attempt to capture a dislodged Angio-Seal in the right SFA with a Spider RX 7 mm filter device (Covidien) via a 7F sheath in the left CFA. 5 Jud et al described a similar technique, using a Spider RX 7 mm filter to capture an embolized Angio-Seal anchor embolized to the posterior tibial artery at the ankle's level.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…There are previous reports of endovascular Angio-Seal removal, but these attempts have been complicated by difficult direct visualization, with partial retrieval or distal embolization following manipulation. 5,6 Rafeh et al describe a fluoroscopic guided attempt to capture a dislodged Angio-Seal in the right SFA with a Spider RX 7 mm filter device (Covidien) via a 7F sheath in the left CFA. 5 Jud et al described a similar technique, using a Spider RX 7 mm filter to capture an embolized Angio-Seal anchor embolized to the posterior tibial artery at the ankle's level.…”
Section: Discussionmentioning
confidence: 99%
“…5,6 Rafeh et al describe a fluoroscopic guided attempt to capture a dislodged Angio-Seal in the right SFA with a Spider RX 7 mm filter device (Covidien) via a 7F sheath in the left CFA. 5 Jud et al described a similar technique, using a Spider RX 7 mm filter to capture an embolized Angio-Seal anchor embolized to the posterior tibial artery at the ankle's level. 7 A similar approach to our technique was performed by Palmer et al 8 Retrieval of a malpositioned Angio-Seal was achieved using a 2-to 4-mm retrieval snare (Atrieve; Argon Medical Devices, Inc) and an 8F sheath via a contralateral access.…”
Section: Discussionmentioning
confidence: 99%
“…There are limited data on endovascular retrieval of an isolated Angio-Seal ® anchor without thrombus or collagen sponge. Abi Rafeh et al [12] reported successful endovascular extraction of newer generation Angio-Seal ® collagen plug and anchor after acute embolization using a Spider ® RX 7-mm filter device (Covidien, Plymouth, MN, USA). We considered aspiration of the anchor and evaluated therefore aspiration catheters of various sizes.…”
Section: Discussionmentioning
confidence: 99%
“…The Celt ACD ® is unique in its high‐visibility on fluoroscopy, and while intended to permit remote re‐puncture, this aided endovascular retrieval in this case. There are previous reports of endovascular removal of Angio‐Seal ® VCDs, but these attempts have been complicated by difficult direct visualization, with partial retrieval or distal embolization following manipulation . Previous endovascular strategies have employed use of the Simpson atherectomy device, gooseneck catheter, and Fogarty balloon retrieval.…”
Section: Discussionmentioning
confidence: 99%