2002
DOI: 10.1021/jf020323+
|View full text |Cite
|
Sign up to set email alerts
|

2-Alkylcyclobutanones as Irradiation Dose Indicators in Irradiated Ground Beef Patties

Abstract: Alkylcyclobutanones have been recognized as chemical markers of irradiated lipid-containing foods since 1970. They are important because they are produced solely as a result of irradiation and not any other processing method. This study investigated the formation of 2-dodecylcyclobutanone (2-DCB) and 2-tetradec-5'-enylcyclobutanone (2-TDCB) in irradiated ground beef patties from commercial and noncommercial sources. Patties were irradiated using a (60)C source (gamma-irradiation) and electron beam irradiation,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

7
48
0
1

Year Published

2004
2004
2021
2021

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 47 publications
(56 citation statements)
references
References 11 publications
7
48
0
1
Order By: Relevance
“…Blanch et al (2009) using SPME-GC-MS found a limit of detection of 0.3 mg/kg 2-DCB. The detection limit for 2-ACBs from beef extracted by SFE (Gadgil et al, 2002(Gadgil et al, , 2005 was not provided but levels of 0.02 mg/kg were reported for a 0.5 g beef sample. Horvatovich et al (2006) compared the detection limit for standards of 2-ACBs and monounsaturated 2-ACBs when analysed using both CI and EI ionisation.…”
Section: Detection Limitmentioning
confidence: 99%
“…Blanch et al (2009) using SPME-GC-MS found a limit of detection of 0.3 mg/kg 2-DCB. The detection limit for 2-ACBs from beef extracted by SFE (Gadgil et al, 2002(Gadgil et al, , 2005 was not provided but levels of 0.02 mg/kg were reported for a 0.5 g beef sample. Horvatovich et al (2006) compared the detection limit for standards of 2-ACBs and monounsaturated 2-ACBs when analysed using both CI and EI ionisation.…”
Section: Detection Limitmentioning
confidence: 99%
“…To reduce the extraction time and improve selective extraction for 2-alkylcyclobutanones, supercritical fluid extraction (Tewfik et al 1999;Horvatovich et al 2000Horvatovich et al , 2002bGadgil et al 2002), accelerated solvent extraction (Obana et al 2005(Obana et al , 2006, and direct solvent extraction (Tewfik 2008) have been employed instead of Soxhlet extraction and have succeeded in a greatly reduced extraction time to about 30-90 min.…”
Section: Limitations Of the Gas Chromatographic Analysis Of Fat-contamentioning
confidence: 99%
“…Although this process is considered a safe food preserving method, to comply with both national and international legislation and to enhance consumer confidence, it is necessary to develop a reliable, convenient, and rapid method to distinguish irradiated from non-irradiated products (Hijaz, Kumar, & Smith, 2010). 2-Alkylcyclobutanones are radiolytic products that include 2-dodecylcyclobutanone (2-DCB) from palmitic acid and 2-tetradecylcyclobutanone (2-TCB) from stearic acid; these compounds have been used to detect irradiated lipid-containing foods (Blanch, Caja, Flores, & Castillo, 2009;Elliott, Hamilton, Stevenson, McCaughey, & Boyd, 1995;Gadgil, Hachmeister, Smith, & Kropf, 2002;Horvatovich, Miesch, Hasselmann, Delinceée, & Marchioni, 2005;Obana, Furuta, & Tanaka, 2005;Soncin et al, 2012;Zhao, Wang, Li, Li, & Ha, 2012) 2-Alkylcyclobutanones are considered unique radiolytic products because they are not formed during cooking or any other heat-processing methods.…”
Section: Introductionmentioning
confidence: 99%