2016
DOI: 10.5935/0100-4042.20160011
|View full text |Cite
|
Sign up to set email alerts
|

Fto Modified Electrodes by Direct Gold Electrodeposition: Production, Characterization and Electrochemical Sensor Aplication

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
1

Year Published

2018
2018
2022
2022

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 0 publications
0
2
0
1
Order By: Relevance
“…Another feature is the low power consumption and small dimensions, making the CCS811 suitable for in situ measurements proposed in this study. First, however, it is necessary to perform compensation of the temperature effect on the CO2 sensor measurements (KOROTCENKOV, 2014;OLIVEIRA et al, 2016;LOWINSOHN et al, 2006). DHT21 has a digital architecture and has a thermistor for temperature measurement with an accuracy of ± 0.5° C. Internally, the thermistors have a ceramic that changes the resistance to the passage of electric current according to the temperature of the environment.…”
Section: Development Hardwarementioning
confidence: 99%
“…Another feature is the low power consumption and small dimensions, making the CCS811 suitable for in situ measurements proposed in this study. First, however, it is necessary to perform compensation of the temperature effect on the CO2 sensor measurements (KOROTCENKOV, 2014;OLIVEIRA et al, 2016;LOWINSOHN et al, 2006). DHT21 has a digital architecture and has a thermistor for temperature measurement with an accuracy of ± 0.5° C. Internally, the thermistors have a ceramic that changes the resistance to the passage of electric current according to the temperature of the environment.…”
Section: Development Hardwarementioning
confidence: 99%
“…However, when submitted to the cyclic voltammetry technique in the absence and presence of the analyte (EG) in alkaline media, the Ni(OH) 2 /AuNp/ rGO/GCE presented a voltammogram with three anodic peaks and three cathodic peaks (Figure 4d). The first and second anodic peaks (1 and 2) observed at -0.07 V and 0.21V, respectively, refer to the adsorption of OHon the gold surface, the peaks 4 and 5 at 0.48 and 0.36 V, respectively, are related to α-Ni(OH) 2 /γ-NiOOH redox pair [67][68][69][70][71] . The peak 3 is related to the EG oxidation and responds to EG concentration.…”
Section: Electrochemical Behavior Of the Electrodes In The Absence And Presence Of Egmentioning
confidence: 99%
“…1 Ele e outros compostos relacionados podem ser determinados e caracterizados por diversos métodos de análises. [7][8][9][10][11][12][13][14]…”
Section: Aspectos Geraisunclassified