2022
DOI: 10.5935/0004-2749.20220051
|View full text |Cite
|
Sign up to set email alerts
|

Development of an application for providing corneal topography reports based on artificial intelligence

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
1
0
1

Year Published

2024
2024
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 0 publications
0
1
0
1
Order By: Relevance
“…The majority of the included studies regarding keratoconus or corneal ectasia diagnosis with AI used data from corneal topography ( 47 , 51 53 , 56 , 57 , 67 , 73 , 74 , 77 , 78 , 83 , 91 , 92 , 94 , 100 ), Scheimpflug-based tomography ( 43 , 45 , 49 , 54 , 55 , 59 , 60 , 62 , 64 , 66 , 70 , 76 , 79 , 80 , 84 , 86 88 , 90 , 95 , 99 ), or optical coherence tomography (OCT) ( 31 , 46 , 50 , 53 , 68 , 69 , 72 , 80 , 84 ) as the input. For example, de Almeida et al.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The majority of the included studies regarding keratoconus or corneal ectasia diagnosis with AI used data from corneal topography ( 47 , 51 53 , 56 , 57 , 67 , 73 , 74 , 77 , 78 , 83 , 91 , 92 , 94 , 100 ), Scheimpflug-based tomography ( 43 , 45 , 49 , 54 , 55 , 59 , 60 , 62 , 64 , 66 , 70 , 76 , 79 , 80 , 84 , 86 88 , 90 , 95 , 99 ), or optical coherence tomography (OCT) ( 31 , 46 , 50 , 53 , 68 , 69 , 72 , 80 , 84 ) as the input. For example, de Almeida et al.…”
Section: Resultsmentioning
confidence: 99%
“…For example, only one specialist determined the presence of keratoconus for the reference standard of some diagnostic accuracy studies, including Almeida Jr. et al., Lucena et al., Lopes et al., Chandapura et al., Cohen et al., Zéboulon et al., Mosa et al., and Zaki et al. ( 45 , 47 , 49 , 53 , 54 , 75 , 87 , 93 ) This could have resulted in biased classification of eyes. Additionally, some studies included a relatively low sample size of study groups, which reduced the power of the study.…”
Section: Discussionmentioning
confidence: 99%
“…We included 19 studies in the systematic review that contained 96,549 images or scans from over 10,500 patients. 5,7,[12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27][28] Five studies assessed the diagnostic performance of DL algorithms using anterior segment OCT images, 5,[17][18][19]26 12 studies using corneal topography images (8 Scheimpflug and 4 Placido disk based), 7,[12][13][14][15][16][20][21][22][23][24]28 and 2 studies using smartphone images (topography 25 and lateral segment images 27 ). Keratoconus grading was reported in 11 studies, 4 of which used the Amsler-Krumeich classification.…”
Section: Study Characteristicsmentioning
confidence: 99%
“…Apesar de enfrentar desafios, como a dificuldade em distinguir certos tipos de astigmatismo devido a padrões não convencionais nas imagens, o aplicativo também serve como uma ferramenta educacional para médicos, melhorando a compreensão e interpretação das condições da córnea. Esta inovação não só melhora a acessibilidade ao diagnóstico oftalmológico como também aumenta sua precisão(Lucena et al, 2021). clínico entre aqueles com resultados anormais, demonstrando o potencial da IA em aprimorar tanto a eficácia quanto a eficiência do cuidado médico em populações vulneráveis.Brazilian Journal of Health Review, Curitiba, v. 7, n. 3, p. 01-13, may/jun., 2024 3.3 NEUROLOGIA A IA no radiodiagnóstico está transformando a forma como os tumores cerebrais são examinados e acompanhados.Brazilian Journal of Health Review, Curitiba, v. 7, n. 3, p. 01-13, may/jun., 2024…”
unclassified