Determination of the force systems produced by different configurations of tear drop orthodontic loops

Abstract: In general, teardrop loops with helix produced lower magnitudes of horizontal force and load/deflection ratio, and higher moment/force ratio than teardrop loops without helix. Among all analyzed variables, metal alloy composition presented greater influence in the horizontal force and in the load/deflection ratio. The moment/force ratio showed to be more influenced by the preactivation of loops for space closure.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
17
0
1

Year Published

2014
2014
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(19 citation statements)
references
References 17 publications
(20 reference statements)
1
17
0
1
Order By: Relevance
“…Beta titanium is less stiff than stainless steel which has been demonstrated by numerous studies. 6,[9][10][11][12][13] The 0.019" × 0.025" wire dimensions produced more force and load deflection rate than 0.017" × 0.025" (Tables 3 and 4, Graph 1). The 0.019" × 0.025" produced approximately 1.4 times more force than 0.017" × 0.025" wire dimensions.…”
Section: Discussionmentioning
confidence: 99%
“…Beta titanium is less stiff than stainless steel which has been demonstrated by numerous studies. 6,[9][10][11][12][13] The 0.019" × 0.025" wire dimensions produced more force and load deflection rate than 0.017" × 0.025" (Tables 3 and 4, Graph 1). The 0.019" × 0.025" produced approximately 1.4 times more force than 0.017" × 0.025" wire dimensions.…”
Section: Discussionmentioning
confidence: 99%
“…Dve osnovne tehnike koje se razlikuju po biomehanici su mehanizam omči za zatvaranje prostora i klizni mehanizam [8]. Omče su inkorporirane u dizajn žičanog luka i imaju ulogu da preko njega prenesu silu koja dovodi do zatvaranja prostora bez pojave trenja [9]. Sanjay i saradnici navode da zatvaranje postekstrakcionih prostora bez pojave trenja, pri čemu se proizvode kontinuirane sile, predstavlja najveću prednost omči [10].…”
Section: Kratak Sadržajunclassified
“…There are various techniques for carrying out this clinical procedure, and proper selection can affect the outcome of the treatment. Two basic techniques that differ in biomechanics are closing loops and sliding mechanics [8].Closing loops are incorporated into the archwire design and transmit force over it to close the space without any friction [9]. Sanjay et al stated that the closure of postextraction spaces without friction, while producing continuous forces, was the biggest advantage of a loop [10].…”
Section: Introductionmentioning
confidence: 99%
“…Additionally, it produces lighter forces. 13 , 20 Nevertheless, it is more sensitive in addition to being influenced by factors that hinder sliding of orthodontic archwires, such as friction, less torque control of anterior teeth and overbite. 21 Adding more torque on the orthodontic archwire and using brackets with greater torque are recommended to control tipping of incisors.…”
Section: Final Considerationsmentioning
confidence: 99%