2015
DOI: 10.1590/s1980-65742015000200012
|View full text |Cite
|
Sign up to set email alerts
|

Reliability of electromyography parameters during stair deambulation in patellofemoral pain syndrome

Abstract: Reliability is essential to all aspects of the measure, as it shows the quality of the information and allows rational conclusions with regard to the data. There has been controversial results regarding the reliability of electromyographic parameters assessed during stair ascent and descent in individuals with patellofemoral pain syndrome (PFPS). Therefore, this study aims to determine the reliability of time and frequency domain electromyographic parameters on both gestures in women with PFPS. Thirty-one wome… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2016
2016
2016
2016

Publication Types

Select...
2

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 40 publications
0
2
0
Order By: Relevance
“…As previously mentioned, PFP is one of the most common diagnoses in sports medicine, accounting for nearly 25% of all identified knee injuries (De Oliveira Silva, Briani, Pazzinatto, Ferrari, Aragão, Albuquerque, et al, 2015a;Pazzinatto et al, 2015;Silva et al, 2015). It is a common problem, encompassing a variety of symptoms without a single identifiable cause (De Oliveira Silva, Briani, Pazzinatto, Ferrari, Aragão, & de Azevedo, 2015b; Witvrouw et al, 2014).…”
Section: Discussionmentioning
confidence: 99%
“…As previously mentioned, PFP is one of the most common diagnoses in sports medicine, accounting for nearly 25% of all identified knee injuries (De Oliveira Silva, Briani, Pazzinatto, Ferrari, Aragão, Albuquerque, et al, 2015a;Pazzinatto et al, 2015;Silva et al, 2015). It is a common problem, encompassing a variety of symptoms without a single identifiable cause (De Oliveira Silva, Briani, Pazzinatto, Ferrari, Aragão, & de Azevedo, 2015b; Witvrouw et al, 2014).…”
Section: Discussionmentioning
confidence: 99%
“…After finding the VM and VL motor points, the skin over the anterior portion of the thigh was cleaned with rubbing alcohol. The electrodes were placed 2 cm below the motor point in the direction of the muscle belly, with a 20 mm interelectrode distance (Pazzinatto et al, 2015). This motor point method for positioning the electrodes is in accordance with the Surface Electromyography for the Non-Invasive Assessment of Muscles (SENIAM) (Hermens et al, 2000).…”
Section: Methodsmentioning
confidence: 99%