2007
DOI: 10.1590/s1806-37132007000500007
|View full text |Cite
|
Sign up to set email alerts
|

Validação de novos valores previstos brasileiros para a espirometria forçada na raça branca e comparação com os valores previstos obtidos por outras equações de referência

Abstract: These results underscore the importance of using prediction equations for spirometry that are appropriate for our population.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0
8

Year Published

2014
2014
2023
2023

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 58 publications
(20 citation statements)
references
References 15 publications
1
11
0
8
Order By: Relevance
“…Measurements were expressed as predicted values. 13 To measure VE, the patient was instructed to breathe normally for one minute through a facial mask connected to the spirometer. TV was determined by dividing VE by the respiratory rate (f).…”
Section: Methodsmentioning
confidence: 99%
“…Measurements were expressed as predicted values. 13 To measure VE, the patient was instructed to breathe normally for one minute through a facial mask connected to the spirometer. TV was determined by dividing VE by the respiratory rate (f).…”
Section: Methodsmentioning
confidence: 99%
“…( 13 ) We measured FEV 1 and FVC, predicted normal values being determined by the use of validated equations. ( 14 ) We measured MEP and MIP at the mouth using a portable spirometer (microQuark; Cosmed, Rome, Italy) under static conditions, in accordance with a validated method. ( 15 ) We measured MEP at TLC and MIP at functional residual capacity, the highest of three valid measurements being recorded.…”
Section: Methodsmentioning
confidence: 99%
“…( 13 ) Foram medidos o VEF 1 e a CVF, e os valores normais previstos foram determinados por meio de equações validadas. ( 14 ) A PEmáx e a PImáx foram medidas na boca com um espirômetro portátil (microQuark; Cosmed, Roma, Itália) em condições estáticas, de acordo com um método validado. ( 15 ) A PEmáx foi medida em CPT e a PImáx foi medida em capacidade residual funcional, sendo registrada a maior de três medidas válidas.…”
Section: Métodosunclassified
“…18 Normality values were related to the Brazilian population. 19 The functional exercise capacity was assessed with the 6MWT according to the guidelines of the American Tho-racic Society. 20 The experimental values obtained were analyzed according to values provided by Enright and Sherrill.…”
Section: Anthropometric Evaluation Pulmonary Function Assessment Anmentioning
confidence: 99%