Dimensionamento de reservatório para aproveitamento de água de chuva: comparação entre métodos da ABNT NBR 15527:2007 e Decreto Municipal 293/2006 de Curitiba, PR

Abstract: Este estudo avaliou a viabilidade do aproveitamento da água das chuvas no Tanque de Provas, utilizado em ensaios de modelos reduzidos de embarcações da Faculdade de Tecnologia de Jahu-Fatec Jahu, SP. O trabalho considerou os dados pluviométricos locais, a área de cobertura para captação e a demanda de água. Foi estimada a necessidade de água no processo de limpeza por filtragem, lavagem e evaporação do Tanque de Provas. O dimensionamento do reservatório foi calculado conforme as metodologias descritas na NBR 1… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0
7

Year Published

2011
2011
2020
2020

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 16 publications
(18 citation statements)
references
References 1 publication
0
11
0
7
Order By: Relevance
“…For the dimensioning of the reservoir were used the NBR 15527/2007 ABNT, 2007) recommendations dealing with covering requirements in urban areas for non-potable purposes. The NBR 15527/2007 contains six methods for sizing of rainwater reservoirs presented in the Annex; such methods are described in that NBR and detailed in Bezerra et. al.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…For the dimensioning of the reservoir were used the NBR 15527/2007 ABNT, 2007) recommendations dealing with covering requirements in urban areas for non-potable purposes. The NBR 15527/2007 contains six methods for sizing of rainwater reservoirs presented in the Annex; such methods are described in that NBR and detailed in Bezerra et. al.…”
Section: Resultsmentioning
confidence: 99%
“…According to Bezerra et al (2010) in Australian Practical Method, the reservoir volume (V R ) is determined by attempts to meet the demand with system trust between 90 and 99%, as recommended by the NBR 15527/2007(ABNT, 2007. According to the equations indicated in the standard, and considering the period of a year that was investigated in these case studies, the container shall meet the demand for at least 11 months a year, to get reliability of 91% (Equations 6 and 7) .…”
Section: Resultsmentioning
confidence: 99%
“…As per Bezerra et al [87], reliability is the relationship between the period in which demand is met with rainwater and the total investigated period, and efficiency is the relationship between the volume of harvested rainwater and the volume of rainwater that did not overflow from the tank. Therefore, reliability is related to the verification of the service to the demand, and efficiency is related the impact of the rainwater harvesting system on runoff.…”
Section: Potential For Potable Water Savingsmentioning
confidence: 99%
“…Although the Brazilian standard on rainwater usage in buildings presents six methods for tank sizing, there are criticisms about them, such as the fact that the results presented by them are very different from each other [87]. According to Dornelles [39], the practical methods in the standard are those that present greater limitations since they adopt ratios of simple proportionality between rainfall and tank capacity, i.e., they do not take the seasonal behaviour of rainfall into account.…”
Section: Potential For Potable Water Savingsmentioning
confidence: 99%
“…O dimensionamento do reservatório é o maior desafio para viabilizar o aproveitamento das águas pluviais, pois é, na maioria dos casos, o item mais caro do sistema (Bezerra et al, 2010;Cohim e Oliveira, 2009;Cohim et al, 2008;Mierzwa et al, 2007;May, 2004;Martinson e Thomas, 2009).…”
Section: Introductionunclassified