2005
DOI: 10.1590/s1678-77572005000200007
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of weight loss and surface roughness of compomers after simulated toothbrushing abrasion test

Abstract: This study aimed at analyzing the compomers wear by an "in vitro" toothbrushing abrasion test. The null hypotheses tested were that there would be no differences in weight loss and no significant changes in surface roughness of the compomers after this test. The utilized commercial brands were Dyract (Dentsply), Dyract AP (Dentsply), Compoglass F (Vivadent), Freedom (SDI), F2000 (3M ESPE), which were compared to the two resin composites Z100 (3M ESPE) and Silux Plus (3M ESPE). Ten cylindrical specimens for eac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0
19

Year Published

2008
2008
2020
2020

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(32 citation statements)
references
References 20 publications
(11 reference statements)
0
13
0
19
Order By: Relevance
“…Several authors 27,28,29,30 have stated the importance of choosing adequate parameters for surface roughness measurements. Because the Ra parameter is limited to horizontal measurements 27,28,29 , different surfaces could present the same roughness values, thus rendering the results questionable.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Several authors 27,28,29,30 have stated the importance of choosing adequate parameters for surface roughness measurements. Because the Ra parameter is limited to horizontal measurements 27,28,29 , different surfaces could present the same roughness values, thus rendering the results questionable.…”
Section: Resultsmentioning
confidence: 99%
“…Because the Ra parameter is limited to horizontal measurements 27,28,29 , different surfaces could present the same roughness values, thus rendering the results questionable. Nevertheless, since this parameter is a routine method 1,14,15,16,17,30 , it was adopted here to facilitate comparisons with previous studies.…”
Section: Resultsmentioning
confidence: 99%
“…Foram simulados no presente estudo 400.000 ciclos, o que corresponde a aproximadamente três anos de escovação (Hossain et al, 2006(Hossain et al, , 2007Wataha et al,1999) e a pressão aplicada de 200g (Amaral et al, 2006;Correr Sobrinho et al, 2001;Garcia et al, 2004;Mondelli et al, 2005;Wang et al, 2004).…”
Section: Discussão Dos Resultadosunclassified
“…No presente estudo, optou-se por reproduzir, através de uma máquina de escovação, condições semelhantes às que ocorrem in situ, por ser este um método efetivo para avaliar a resistência ao desgaste de materiais restauradores tais como: resinas compostas, cimento de ionômero de vidro, cerâmicas, titânio, ouro, amálgama e resinas acrílicas (Amaral et al, 2006;Heintze;Forjanic, 2005;Hossain et al 2006;Johannsen et al, 1992;Mondelli et al,2005;Yesil Duymus et al, 2006).…”
Section: Discussionunclassified
“…A cada 50000 ciclos, os corpos de prova eram removidos da barra e novamente limpos com álcool isopropílico e máquina de ultrassom por mais 20 minutos, sendo pesados por 3 vezes, obtendo-se assim as massas parciais e avaliada suas rugosidades superficiais. Este procedimento foi repetido até alcançado 200.000 ciclos, equivalentes a 10 anos de escovação (MONDELLI et al, 2005).…”
Section: Métodosunclassified