2018
DOI: 10.1590/s1517-707620170001.0325
|View full text |Cite
|
Sign up to set email alerts
|

Influência do aditivo espumígeno na dosagem e nas propriedades do concreto celular aerado

Abstract: RESUMO O concreto celular aerado ou espumoso (CCE) é um concreto leve que se diferencia dos demais pela presença de espuma no interior das argamassas. Essa espuma, formada por bolhas de ar, influencia o comportamento desses concretos. Parâmetros como dosagem do aditivo, volume de bolhas geradas e outros precisam ser mais bem compreendidos e determinados, pois influenciam diretamente na formulação, trabalhabilidade, densidade e resistência do CCE. Este artigo apresenta um estudo da influência de diferentes dosa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2019
2019
2019
2019

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 4 publications
0
2
0
Order By: Relevance
“…Figure 2 shows the experimental apparatus used to determine thermal conductivity, which was done by using a hot thermal wire on the surface. This technique has already been corroborated as a variant of the parallel hot wire by several authors (GRAZZINI;BALOCCO, 1995;AKIYOSHI et al, 2001;SANTOS, 2002;FRANCO, 2007;SACHT et al, 2010;LERMEN et al, 2019) and is characterized as being a direct method that detects the transient temperature. The experimental system consists of two multimeters to determine the electric current and voltage; two samples in the form of a parallelepiped; a hot wire (0.5 mm diameter kanthal) connected to a power source; four temperature sensors (NTC); and a data acquisition system.…”
Section: Characterization Of the Blocksmentioning
confidence: 89%
See 1 more Smart Citation
“…Figure 2 shows the experimental apparatus used to determine thermal conductivity, which was done by using a hot thermal wire on the surface. This technique has already been corroborated as a variant of the parallel hot wire by several authors (GRAZZINI;BALOCCO, 1995;AKIYOSHI et al, 2001;SANTOS, 2002;FRANCO, 2007;SACHT et al, 2010;LERMEN et al, 2019) and is characterized as being a direct method that detects the transient temperature. The experimental system consists of two multimeters to determine the electric current and voltage; two samples in the form of a parallelepiped; a hot wire (0.5 mm diameter kanthal) connected to a power source; four temperature sensors (NTC); and a data acquisition system.…”
Section: Characterization Of the Blocksmentioning
confidence: 89%
“…According to the Brazilian Portland Cement Association (ABCP, 2002), for a foamed cellular concrete made on site, the range of the admitted percentage of void volume is between 35% and 45%. Currently, a draft project (ABNT, 2013b) lays down that foamed cellular concrete, when molded in place to seal multi-floor buildings, may have a maximum of 37% voids (SILVA et al, 2018).…”
Section: Dry and Wet Densitymentioning
confidence: 99%