2010
DOI: 10.1590/s1516-18462010005000076
|View full text |Cite
|
Sign up to set email alerts
|

Respostas falso-positivas na triagem auditiva neonatal universal: possíveis causas

Abstract: RESUMOObjetivo: avaliar a ocorrência de respostas falso-positivas na Triagem Auditiva dentro de uma maternidade particular, suas possíveis causas e soluções. Método: foram avaliados 1.110 recém-nascidos eutróficos entre 6 e 48 horas de vida no berçário, com o analisador de Emissões Otoacústicas Evocadas Transientes (EOATE) modelo Echochek da Ilodynamics Ltd. Na ausência de resposta, foi realizada a manipulação do meato acústico externo (Manobra Facilitadora) e colhido novo resultado. Os que falharam foram rete… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
9
2
5

Year Published

2011
2011
2016
2016

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 20 publications
(18 citation statements)
references
References 13 publications
2
9
2
5
Order By: Relevance
“…As far as the gender variable is concerned, we did not find significant differences, which is in agreement with some studies in the literature 23 . Concerning the ears tested, failures in the newborn hearing screening were similar in both ears, which are different from what was obtained from one of the compiled studies 24 , which found a greater occurrence of failures in the left ear.…”
Section: Discussioncontrasting
confidence: 99%
“…As far as the gender variable is concerned, we did not find significant differences, which is in agreement with some studies in the literature 23 . Concerning the ears tested, failures in the newborn hearing screening were similar in both ears, which are different from what was obtained from one of the compiled studies 24 , which found a greater occurrence of failures in the left ear.…”
Section: Discussioncontrasting
confidence: 99%
“…. These associations are relevant, since the inclusion of the frequency analysis of 1.500 Hz makes it difficult to determine whether the TOAEs are absent due to lack of cochlea active process or due to external and/or internal factors mentioned before 19,20 .…”
Section: Resultsmentioning
confidence: 99%
“…Furthermore, the present study was concerned with controlling procedures that may influence the "pass-fail" results in NHS testing, such as probe adjustment, using a "facilitation maneuver", probe monitoring and stability 22,25,26 . Hours of life (≥24 hours), the newborn's state of consciousness and noise were also controlled 12,27,28 .…”
Section: Resultsmentioning
confidence: 99%