2000
DOI: 10.1590/s1516-14392000000300003
|View full text |Cite
|
Sign up to set email alerts
|

Surface analysis of titanium dental implants with different topographies

Abstract: Cylindrical dental implants made of commercially pure titanium were analysed in four different surface finishes: as-machined, Al2O3 blasted with Al2O3 particles, plasma-sprayed with titanium beads and electrolytically coated with hydroxyapatite. Scanning electron microscopy (SEM) with Energy Dispersive X-ray Analysis (EDX) revealed the topography of the surfaces and provided qualitative results of the chemical composition of the different implants. X-ray Photoelectron Spectroscopy (XPS) was used to perform che… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
3
0

Year Published

2004
2004
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 15 publications
(3 citation statements)
references
References 11 publications
(11 reference statements)
0
3
0
Order By: Relevance
“…The Al 2 O 3 blasted specimen spectrum (Fig. 6) showed contamination with aluminum, also identified by SEM, which was associated with the alumina particles from the blasting process [57]. The literature review of the spectroscopic analyses [71][72][73] shows that the surface oxide consists mainly of TiO 2 , which is a stable compound, resistant to chemical attack from most substances.…”
Section: Discussionmentioning
confidence: 92%
See 1 more Smart Citation
“…The Al 2 O 3 blasted specimen spectrum (Fig. 6) showed contamination with aluminum, also identified by SEM, which was associated with the alumina particles from the blasting process [57]. The literature review of the spectroscopic analyses [71][72][73] shows that the surface oxide consists mainly of TiO 2 , which is a stable compound, resistant to chemical attack from most substances.…”
Section: Discussionmentioning
confidence: 92%
“…Surface treatments are the most important factors that govern the strength of adhesive joints. The high rough surfaces with so-called macrosized topography are proven to stabilize the implant during the initial phase after implementation, providing enough space for new cell proliferation and bone tissue formulation [57][58][59]. The microsized topography is obtained by various surface modifications.…”
Section: Discussionmentioning
confidence: 99%
“…SEM picture showing the surface of the implant: (x 3.000). a) As-machined; b) Al2O3 blasted; c) Plasma-sprayed with titanium; d) Electrolytically coated with hydroxyapatite 12.…”
mentioning
confidence: 99%