2010
DOI: 10.1590/s1413-78522010000100010
|View full text |Cite
|
Sign up to set email alerts
|

Esteira com velocidade controlada para captação da marcha

Abstract: Histological and electrophysiological methods for evaluation of peripheral nerve regeneration do not faithfully reproduce the functional index of limbs, even in controlled experimental conditions. Some methods of functional evaluation have been proposed, but their correlation to histological and electrophysiological data is not completely established, requiring more investigations with improvement of collection, management and processing of obtained data. In this study we developed a treadmill with controlled … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
1

Year Published

2011
2011
2020
2020

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(3 citation statements)
references
References 19 publications
(32 reference statements)
0
2
0
1
Order By: Relevance
“…A treadmill with controlled speed developed by Monte-Raso et al 16 was used to capture gait for the functional assessment. The treadmill, with speed adjustment from 0 to 14 meters per minute, was made in acrylic, whose transparency allowed the filming of the animals' gait using a 1.3 megapixel webcam coupled to a portable computer.…”
Section: Methodsmentioning
confidence: 99%
“…A treadmill with controlled speed developed by Monte-Raso et al 16 was used to capture gait for the functional assessment. The treadmill, with speed adjustment from 0 to 14 meters per minute, was made in acrylic, whose transparency allowed the filming of the animals' gait using a 1.3 megapixel webcam coupled to a portable computer.…”
Section: Methodsmentioning
confidence: 99%
“…The recordings were done using a webcam, plugged through a USB cable directly connected to a portable computer. 14 After recording, an image of each animal was selected and evaluated through the Image Pro-plus 6.0 (Media Cybernetics, Georgia, United States) program with variable measurements as suggested by Bain et al, 15 Animal Euthanasia On the last day of the experiment (37th), all animals were weighed and anesthetized; dissection was done followed by the removal of 2 cm of the sciatic nerve, distal to the compression procedures for morphological and oxidative stress of the nerve tissue analysis. Soon after, the animals were euthanized by guillotine decapitation and their left hemimandibles were collected for posterior radiographic analysis.…”
Section: Sciatic Functional Indexmentioning
confidence: 99%
“…Para a análise funcional foi utilizada uma esteira com velocidade controlada (Insight®, Brasil), com base em acrílico, possibilitando o registro da marcha por uma webcam 11 . Foi selecionada uma imagem, de cada animal, e avaliada no programa Image Pro-plus 6.0, com a mensuração de: comprimento da pegada (PL), a abertura total dos dedos, do 1º ao 5º (TS) e a abertura dos dedos intermediários, do 2º ao 4º (IT), do membrolesionado ou experimental (E) e no lado contralateral ou normal (N).…”
Section: íNdice Funcional Do Isquiático (Ifc)unclassified