2005
DOI: 10.1590/s0103-97332005000100014
|View full text |Cite
|
Sign up to set email alerts
|

Mechanism of insulin emission in matrix assisted laser ionization

Abstract: In the present paper the emission of intact insulin quasi-molecular ion [M+H] + during laser ablation (MALDI) is studied. It was observed in particular that the insulin TOF molecular peak increases as the laser power increases. The DE-Vestal method for the initial velocity measurements was improved theoretically including the distance (d0) until the free expansion regime can be considered. According to the present analysis, the v0 parameter given by the DE-Vestal method is interpreted as the initial velocity … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2006
2006
2006
2006

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 12 publications
(19 reference statements)
0
1
0
Order By: Relevance
“…Figure presents a sectional view of the simulated electrodes, the potential contours, and the ion trajectories in the region of the duplex MALDI source. The initial kinetic energy of the ions in the + z direction was defined by the empirical results in the literature. Since no additional focusing device is installed in the field-free drift tubes, the configuration of the duplex source exhibits many unique features for optimizing the transmission efficiency, reducing the beam divergence, and extending the mass working range. According to the predictions for the current configuration, the appropriate initial ionic energy is below 5 eV; for ions of higher initial energy, such as heavy biomolecules, a higher extraction potential is recommended.…”
Section: Resultsmentioning
confidence: 99%
“…Figure presents a sectional view of the simulated electrodes, the potential contours, and the ion trajectories in the region of the duplex MALDI source. The initial kinetic energy of the ions in the + z direction was defined by the empirical results in the literature. Since no additional focusing device is installed in the field-free drift tubes, the configuration of the duplex source exhibits many unique features for optimizing the transmission efficiency, reducing the beam divergence, and extending the mass working range. According to the predictions for the current configuration, the appropriate initial ionic energy is below 5 eV; for ions of higher initial energy, such as heavy biomolecules, a higher extraction potential is recommended.…”
Section: Resultsmentioning
confidence: 99%