2006
DOI: 10.1021/ac061213v
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous Mass Analysis of Positive and Negative Ions Using a Dual-Polarity Time-of-Flight Mass Spectrometer

Abstract: Positive and negative ions produced from matrix-assisted laser desorption/ionization (MALDI) were simultaneously measured using a newly developed dual-polarity time-of-flight mass spectrometer. This instrument is effective not only for express and comprehensive mass analysis but also for studying the ionization mechanisms of biomolecules. It comprises two identical time-of-flight mass analyzers located symmetrically about a MALDI ion source. The ion optics are arranged to be able to extract positive and negati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
19
0

Year Published

2007
2007
2023
2023

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 23 publications
(19 citation statements)
references
References 29 publications
0
19
0
Order By: Relevance
“…Two home-made synchronized dual-polarity mass spectrometers were used in this work, namely (1) a dual-polarity time-of-flight mass spectrometer (DTOFMS) reported previously [11], and (2) a simplified DTOFMS. Both instruments were equipped with MALDI ion sources at the instrument centers.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Two home-made synchronized dual-polarity mass spectrometers were used in this work, namely (1) a dual-polarity time-of-flight mass spectrometer (DTOFMS) reported previously [11], and (2) a simplified DTOFMS. Both instruments were equipped with MALDI ion sources at the instrument centers.…”
Section: Methodsmentioning
confidence: 99%
“…Synchronized dual-polarity MALDI-TOF mass spectrometry was utilized in this work to record all ions produced under various ionization conditions. The use of synchronized dual-polarity MALDI-TOF mass spectrometry has been successfully demonstrated previously [11] to allow unambiguous examination of counter ions; it allows all ions from every MALDI event to be recorded simultaneously. This feature was essential in this work because uncertainties due to low reproducibility were eliminated.…”
Section: Atrix-assisted Laser Desorption/ionizationmentioning
confidence: 99%
See 1 more Smart Citation
“…Polarity switching [2] is an approach to monitor positive and negative ions alternatively by a mass spectrometer. It is utilized with liquid-chromatographic systems to identify protein modifications [3,4], metabolites [5], and environmental hazards [6], but the instrument performance declines due to duty cycle problems, and the few seconds required for signal recovery after every such switch.The best strategy to obtain positive and negative mass spectra is to employ contemporaneous dual-polarity (DP) ion detection [7,8]. The only DP ionization approach involving liquid samples is the field-induced droplet ionization (FIDI) [9], in which positive and negative liquid jets are produced from falling droplets within a strong d.c. electric field.…”
mentioning
confidence: 99%
“…The best strategy to obtain positive and negative mass spectra is to employ contemporaneous dual-polarity (DP) ion detection [7,8]. The only DP ionization approach involving liquid samples is the field-induced droplet ionization (FIDI) [9], in which positive and negative liquid jets are produced from falling droplets within a strong d.c. electric field.…”
mentioning