2006
DOI: 10.1590/s0103-64402006000100012
|View full text |Cite
|
Sign up to set email alerts
|

Effect of water storage on tooth displacement in maxillary complete dentures

Abstract: The purpose of this study was to investigate the effect of water storage at 37 degrees C (1 week, 1 month and 3 months) on tooth displacement in maxillary complete dentures. Ten maxillary dentures were constructed with Clássico acrylic resin using the conventional method of packing in metallic flasks. Metallic reference pins were placed in the incisal border of the central incisors (I), labial cusp of the first premolars (PM), and mesiolabial cusp of the second molars (M). Twelve hours after final flask closur… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
12
0
2

Year Published

2006
2006
2018
2018

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 16 publications
(15 citation statements)
references
References 15 publications
1
12
0
2
Order By: Relevance
“…Measurements were made before and after 6 months of storage in distilled water, at three different points: the crests of the right (A) and left (B) ridges, and the median region of the palate (M). The results of this investigation are in agreement with those of previous studies (3,5,(8)(9)(10)(11)(12)(13)(14)(15)(16). The greatest dimensional change (0.3109 mm) between the resin base and the plaster cast occurred in the median region of the palate (M).…”
Section: Discussionsupporting
confidence: 91%
See 1 more Smart Citation
“…Measurements were made before and after 6 months of storage in distilled water, at three different points: the crests of the right (A) and left (B) ridges, and the median region of the palate (M). The results of this investigation are in agreement with those of previous studies (3,5,(8)(9)(10)(11)(12)(13)(14)(15)(16). The greatest dimensional change (0.3109 mm) between the resin base and the plaster cast occurred in the median region of the palate (M).…”
Section: Discussionsupporting
confidence: 91%
“…Whereas in the studies of Goodkind and Schulte (15) immersion in water did not produce significant dimensional changes in resin denture bases. An study developed by Consani et al (16) showed that the water storage for a period of 90 days did not promote significant dimensional changes in the teeth distances when compared to the deflasking period. The results found in this study (Tables 1-3) must be related to the long period of immersion in water (180 days), which resulted in increased dimensional changes with expansion of denture bases, causing major disadaptation (17).…”
Section: Discussionmentioning
confidence: 99%
“…The association between gypsum or silicone and water storage did not alter the distances between teeth, except for the PM-PM distance after a 3-month water storage period with silicone investment 2 . Recent work had suggested that teeth displacement due to water immersion is also influenced by other factors such as base thickness, palate form, and difference in the stress releasing induced in different parts of the flask 6 . It may be speculated that the difference observed in the RPM-RM distance would not be detected by the patients during clinical use.…”
Section: Discussionmentioning
confidence: 99%
“…We suppose that these differences are related to the methodology applied to measure tooth displacement in the present study, which was based on tooth inclination angles, instead of linear measurements. Also, it is possible that other variables present during denture processing, as flask closure method 6,7 , post‐pressing time 6 , flask cooling method 7 , water storage 5 , and flasking and polymerisation techniques 8 , may have exerted more influence on polymerisation shrinkage, relief of internal strains after denture deflasking, and consequently molar teeth displacement, than the effects because of differences among investing materials and flask designs evaluated in this study.…”
Section: Discussionmentioning
confidence: 99%
“…These changes may result in traumatic occlusion, irregular distribution of occlusal stresses on underlying tissues, and alterations of dental function, denture comfort, and chewing efficiency 4 . Many studies have investigated tooth displacement and its relationship with the variables involved in denture construction, as flask closure 5,6 , flask cooling method and deflasking procedure 7 , post‐pressing time 8 , water storage 5 and polymerisation techniques 8 , but an ideal protocol that leads to minimum changes has not been established.…”
Section: Introductionmentioning
confidence: 99%