2011
DOI: 10.1590/s0103-50532011001000014
|View full text |Cite
|
Sign up to set email alerts
|

Constant-current coulometry and ion chromatography bromide determination to characterize the purity of the potassium chloride

Abstract: A coulometria é considerada o método de maior qualidade metrológica para medição de quantidade de substância de padrões primários. Entretanto, a contaminação de sais de elevada pureza está presente em níveis traços sendo necessária a sua identificação e quantificação. Este trabalho apresenta os estudos desenvolvidos pelo Inmetro (Instituto Nacional de Metrologia, Normalização e Qualidade Industrial, Brasil) para determinar a pureza do cloreto de potássio (KCl) por titulação coulométrica a corrente constante, a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 12 publications
0
4
0
Order By: Relevance
“…The procedures for characterizing the candidate CRM of KCl were previously described [6]. The electrochemical reactions for the coulometric titration of KCl were similar to the reactions (2) and (3) presented before; however, it is worth emphasizing that in this case, the AgCl was precipitated on a high-purity silver electrode without the presence of light since the AgCl could undergo degradation, interfering in the coulometric results [25,33].…”
Section: Characterization Of the Candidate Crm Of Kclmentioning
confidence: 99%
See 2 more Smart Citations
“…The procedures for characterizing the candidate CRM of KCl were previously described [6]. The electrochemical reactions for the coulometric titration of KCl were similar to the reactions (2) and (3) presented before; however, it is worth emphasizing that in this case, the AgCl was precipitated on a high-purity silver electrode without the presence of light since the AgCl could undergo degradation, interfering in the coulometric results [25,33].…”
Section: Characterization Of the Candidate Crm Of Kclmentioning
confidence: 99%
“…As a consequence, chemical laboratories require suitable certified reference materials (CRMs) for calibration [2,3], method development [4], validation [5], and quality control [6,7]. In volumetric analyses, which are among the most widely used analytical techniques for determining the concentration of solutions [8][9][10][11], primary standards or CRMs are needed to standardize the reagent solution-the titrant-for stoichiometrically reacting with the analyte in an unknown solution-the solution being titrated-to accurately determine the analyte's concentration.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…For coulometric titration, a silver rod of high purity (99.999%) was required to en-sure high current efficiency [3] and the exposure of electrolytic product (AgCl) would cause errors because of photodecomposition [4]. In another study of purity valuation of KCl by constant-current coulometric titration, bromide was titrated the same as chloride, and the mass fraction of chloride was over evaluated [5]. In Germany, inductively coupled plasma (isotope dilution) sector field mass spectrometry, ICP-(ID) SFMS, was established as a candidate reference measurement procedure for serum chloride [6].…”
Section: Introductionmentioning
confidence: 99%